S'abonner

Paraplane analysis from precordial three-dimensional echocardiographic data sets for rapid and accurate quantification of left ventricular volume and function: A comparison with magnetic resonance imaging - 08/09/11

Doi : 10.1016/S0002-8703(99)70469-2 
Youssef F.M. Nosir, MD, Jaap Stoker, MD, PhD, Jaroslaw D. Kasprzak, MD, Maarten H. Lequin, MD, Anita Dall’Agata, MD, Folkert J. Ten Cate, MD, FACC, Jos R.T.C. Roelandt, MD, FACC
Rotterdam, The Netherlands, and Cairo, Egypt 
From the Thoraxcenter, Division of Cardiology and the Department of Radiology, University Hospital Rotterdam-Dijkzigt; the Erasmus University; and the Cardiology Department, Al-Hussein University Hospital, Al-Azhar University 

Abstract

Objectives Three-dimensional echocardiography (3DE) calculates left ventricular volumes (LVV) and ejection fraction (EF) without geometric assumptions, but prolonged analysis time limits its routine use. This study was designed to validate a modified 3DE method for rapid and accurate LVV and EF calculation compared with magnetic resonance imaging (MRI). Methods Forty subjects included 15 normal volunteers (group A) and 25 patients with segmental wall motion abnormalities and global hypokinesis caused by ischemic heart disease (group B) who underwent 3DE with precordial rotational acquisition technique (2-degree interval with electrocardiographic and respiratory gating) and MRI at 0.5 T, electrocardiogram (ECG)-triggered multislice multiphase T1-weighted fast field echo. End-diastolic and end-systolic LVV and EF were calculated from both techniques with Simpson’s rule by manual endocardial tracing of equidistant parallel left ventricular short-axis slices. Slicing from the 3DE data sets were done by both 2.9-mm slice thickness (method 3DE-A) and by 8 equidistant short-axis slices (method 3DE-B); for MRI analysis, 9-mm slice thickness was used. Results Analysis time required for manual endocardial tracing of end-diastolic and end-systolic short-axis slices was 10 minutes for the 3DE-B method compared with 40 minutes by the 3DE-A method. For all 40 subjects the mean ± SD of end-diastolic LVV (mL) were 181 ± 76, 179 ± 73, and 182 ± 76; for end-systolic LVV (mL), 120 ± 76, 120 ± 75, and 122 ± 77; and for EF (%), 39 ± 18, 38 ± 18, and 38 ± 18 for MRI, 3DE-A, and 3DE-B methods, respectively. The differences between 3DE-A and 3DE-B with MRI for calculating end-diastolic and end-systolic LVV and EF were not significant for the whole group of subjects as well as for the subgroups. The 3DE-B method had excellent correlation and close limits of agreement with MRI for calculating end-diastolic and end-systolic LVV and EF: r = 0.98 (–1.3 ± 26.6), 0.99 (–1.6 ± 21.2), and 0.99 (0.2 ± 5.2), respectively. The correlation between 3DE-A and MRI were r = 0.97, 0.98, and 0.98, and the limits of agreement were –1.4 ± 36, –0.6 ± 26, and 0.6 ± 8 for calculating end-diastolic and end-systolic LVV and EF, respectively. In addition, excellent correlation and close limits of agreement between 3DE-A and 3DE-B with MRI for LVV and EF calculation was also found for the subgroups. Intraobserver and interobserver variability (SEE) of MRI for calculating end-diastolic and end-systolic LVV and EF were 6.3, 4.7, and 2.1; and 13.6, 11.5, and 4.7; respectively, whereas that for 3DE-B were 3.1, 4.4, and 2.2; and 6.2, 3.8, and 3.6; respectively. Comparable observer variability was also found for the A and B subgroups. Conclusions The 3DE-A and 3DE-B methods have excellent correlation and close limits of agreement with MRI for calculating LVV and EF in both normal subjects and cardiac patients. The 3DE-B method by paraplane analysis with 8 equidistant short-axis slices has observer variability similar to MRI and reduces the 3DE analysis time to 10 minutes, therefore offering a rapid, reproducible, and accurate method for LVV and EF calculation. (Am Heart J 1999;137:134-43.)

Le texte complet de cet article est disponible en PDF.

Plan


 Dr. Nosir is supported by The Nuffic, The Hague, The Netherlands.
 Reprint requests: Youssef F.M. Nosir, MD, Thoraxcenter, Ba 302, Dr Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.
 4/1/91747


© 1999  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 137 - N° 1

P. 134-143 - janvier 1999 Retour au numéro
Article précédent Article précédent
  • Cardiovascular responses to exercise in children and adolescents with myocardial dysfunction
  • Thomas Rowland, James Potts, Terri Potts, Jochen Son-Hing, Grant Harbison, George Sandor
| Article suivant Article suivant
  • Clinical applications of transpulmonary contrast echocardiography
  • Michael L. Main, Paul A. Grayburn

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.