THREE-DIMENSIONAL COMPUTED TOMOGRAPHY FOR PLANNING UROLOGIC SURGERY - 08/09/11

Doi : 10.1016/S0094-0143(05)70437-7 
Geoffrey S. Young, MD a, Stuart G. Silverman, MD a, Joachim Kettenbach, MD a, Nobuhiko Hata, MD a, Polina Golland, MD, PhD c, Ferenc A. Jolesz, MD a, Kevin R. Loughlin, MD b, Ron Kikinis, MD a
a Departments of Radiology (GSY, SGS, JK, NH, FAJ, RK) 
b Surgery (KRL), Brigham and Women's Hospital, Harvard Medical School, Boston 
c the Artificial Intelligence Laboratory, Massachusetts Institute of Technology (PG), Cambridge, Massachusetts 

Résumé

The development and marketing of new volumetric computed tomography (CT) scanners in 1990 made it possible to perform three-dimensional (3-D) imaging of the abdomen without respiratory artifacts and with clarity similar to that achieved in the musculoskeletal and central nervous systems by conventional scanners.6 Before 1990, all CT scanners had x-ray tubes that were connected to the machine's gantry by electrical cables. This limited the excursion of the tube in any one direction because continuous rotation would wind the cables into a knot. Thus, conventional CT scanning is performed by executing a series of individual CT scan slices during which patients are instructed to hold their breath. Between scans the table is moved forward a certain distance and the process is repeated. If the breath holds are not identical, the imaged organ or region contains gaps or skip areas. This limitation is termed “respiratory misregistration.” The technical advantage that made volumetric CT possible was the development of a continuously rotating x-ray tube with slip rings. Slip rings are a pair of matched rings on the tube and gantry that can rotate past one another without limit. This allows for continuous rotation of the tube and the ability to perform a continuous x-ray exposure as the patient is moved forward through the CT gantry. The resulting exposure forms a path that looks like a spiral or helix; hence, today volumetric CT scanning often is referred to as “spiral” or “helical” CT. Spiral CT acquires data in a region of interest using a single continuous x-ray exposure that is fast enough to be executed during a single breath hold, as the patient moves through the gantry, so that respiratory misregistration is eliminated. An entire body region is imaged and a continuous volume of CT data obtained. The resulting volumetric CT data set can be used to create axial images at a desired slice thickness and at a desired increment. Standard axial images from spiral CT of the urinary tract have been shown to be helpful in the diagnosis and staging of renal masses and are now routinely used for evaluation of renal lesions.15, 16 However, the same spiral CT data can be reformated in multiple planes or in three dimensions.

Although newer 3-D reconstruction techniques retain more data than did older reformatted display methods, 3-D images cannot contain more information than appropriately filmed axial images from the same source data set. Thus, with the possible exception of CT angiography and future developments in virtual endoscopy, 3-D images, by themselves, are of limited diagnostic utility. However, 3-D imaging of the urinary tract is useful in surgical planning, because it allows surgeons to visualize 3-D anatomic relationships clearly. 3-D images created from the same spiral CT data sets for diagnosis and staging of renal masses have been used to create color-coded 3-D surface renderings of renal masses and surrounding structures for surgical planning of partial nephrectomy.1 A preliminary investigation and one published case report9 have shown that this technique can help the urologist locate small renal masses and can help delineate the relationship between a mass and the urinary collecting system during operative planning. Currently, in addition to standard spiral CT, conventional preoperative assessment of a patient before a partial nephrectomy may include aortography and selective renal angiography to determine the number, location, and pattern of branching of renal vessels. Intravenous pyelography also may be indicated to evaluate the anatomic relationship of any renal masses to the intrarenal collecting system and proximal ureter. Someday, 3-D rendering of the same spiral CT data set used to diagnose the tumor may be able to display the relationship between the tumor and the renal parenchyma, vasculature, and collecting system, thus obviating the need for these additional tests.

Le texte complet de cet article est disponible en PDF.

Plan


 Address reprint requests to Stuart G. Silverman, MD Department of Radiology Brigham and Women's Hospital Harvard Medical School 45 Francis Street Boston, MA 02115
The authors wish to acknowledge the following grants NIH PO1 CA 67165-01A1 (RK, FAJ), PO1 AG04953-14 (RK), NSF BES-9631710 (RK), DARPA F41624-96-2-0001 (RK, FAJ) and Austrian Science Fund, Project Jo 1315-MED (JK), Japan Society for Promotion of Science, Tokyo, Japan (NH).


© 1998  W. B. Saunders Company. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 25 - N° 1

P. 103-111 - février 1998 Retour au numéro
Article précédent Article précédent
  • LAPAROSCOPIC SURGERY : Transition to the Future
  • Richard M. Satava, Shaun B. Jones
| Article suivant Article suivant
  • OPEN-CONFIGURATION MR IMAGING, INTERVENTION, AND SURGERY OF THE URINARY TRACT
  • Terence Z. Wong, Stuart G. Silverman, Julia R. Fielding, Clare M.C. Tempany, Kullervo Hynynen, Ferenc A. Jolesz

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.