S'abonner

PRACTICAL CORONARY PHYSIOLOGY : Clinical Application of the Doppler Flow Velocity Guide Wire - 10/09/11

Doi : 10.1016/S0733-8651(05)70320-9 
Richard G. Bach, MD, Morton J. Kern, MD

From the Division of Cardiology, and the J. G. Mudd Cardiac Catheterization Laboratory, St. Louis University School of Medicine, St. Louis, Missouri


Résumé

The clinical manifestations of coronary artery disease result from an impairment of blood flow by coronary obstructive lesions. As a diagnostic technique, coronary angiography provides essential information regarding the presence, location, and extent of such epicardial lesions but remains an imperfect tool for diagnosing their functional significance.71 Angiographic images only indirectly visualize plaque and are subject to interobserver variability in interpretation.75 Uncertainty regarding lesional functional significance and, therefore, the need for intervention can be especially problematic among stenoses with intermediate severity or complex morphology.

To address these limitations, adjunctive techniques have been developed to improve on conventional angiography. Computer-assisted quantitative angiographic analysis (QCA) and intravascular ultrasound enhance the ability to define lesion geometry. Although these techniques provide detailed geometric analyses of coronary lesions, both remain limited to morphologic data, and physiologic consequences must be extrapolated using assumptions based on fluid dynamic principles that are difficult to apply to the coronary arteries of patients. Methods directed at the measurement of coronary blood flow have offered a potential advantage by targeting coronary physiology directly. The development of catheter-based ultrasound technology for quantitative measurement of blood flow has made physiologic coronary analyses practicable in patients. By miniaturization of this technology and refinement of signal processing, the Doppler-tipped angioplasty guide wire (FloWire, Cardiometrics, Inc, Mountain View, CA) has emerged as a significant advance, providing a clinically useful tool for the evaluation of coronary pathophysiology during cardiac catheterization and intervention. This article focuses on information supporting clinical application of coronary flow velocity measurements using the flow velocity guide wire.

Le texte complet de cet article est disponible en PDF.

Plan


 Address reprint requests to Richard G. Bach, MD, Division of Cardiology, Department of Internal Medicine, St. Louis University Health Sciences Center, 3635 Vista Avenue at Grand, St. Louis, MO 63110


© 1997  W. B. Saunders Company. Publié par Elsevier Masson SAS. Tous droits réservés.© 1994  © 1993  © 1993  © 1993  © 1994  © 1993  © 1993  © 1993  © 1993  © 1996 
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15 - N° 1

P. 77-99 - février 1997 Retour au numéro
Article précédent Article précédent
  • INTRAVASCULAR ULTRASOUND : Three-Dimensional Applications and Forward Viewing
  • David D. McPherson, Bonnie J. Kane, From the Division of Cardiology, Northwestern University Medical School, and Northwestern Memorial Hospital (DDM); and the Feinberg Cardiovascular Institute, Northwestern University (BJK), Chicago, Illinois
| Article suivant Article suivant
  • CLINICAL APPLICATION OF CORONARY FLOW RESERVE USING AN INTRACORONARY DOPPLER GUIDE WIRE
  • James D. Joye, Douglas S. Schulman, From the Department of Medicine, Allegheny University, Allegheny General Hospital, Pittsburgh, Pennsylvania

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.