S'abonner

Noninvasive, Three-Dimensional Visualization of Coronary Artery Bypass Grafts by Electron Beam Tomography - 10/09/11

Doi : 10.1016/S0002-9149(97)00003-9 
Stephan Achenbach, MD a, , Werner Moshage, MD a, Dieter Ropers, MD a, Jörg Nossen, MD a, Kurt Bachmann, MD a
a Medizinische Klinik II, Universität Erlangen Nürnberg (Department of Cardiology, University of Erlangen-Nürnberg), Erlangen, Germany 

*Stephan Achenbach, MD, Medizinische Klinik II mit Poliklinik, Universität Erlangen-Nürnberg, Östliche Stadtmauerstrasse 29, 91054 Erlangen, Germany.

Abstract

Electron beam tomography (EBT, ultrafast computed tomography [CT], cine CT) combines unique temporal and high spatial resolution and is especially well suited for cardiac imaging. We established and evaluated a protocol for the noninvasive visualization and assessment of aortocoronary artery bypass grafts. Twenty-five patients with 56 bypass grafts were studied by EBT. Forty contiguous cross-sectional images were acquired triggered to the electrocardiogram during breathhold and intravenous injection of contrast agent. Three-dimensional reconstructions of the heart and bypass grafts were performed and compared with selective angiography of the bypass grafts. In 1 patient with 2 bypass grafts, a technically inadequate EBT examination was obtained. In the remaining patients (54 grafts), all 13 bypass occlusions were diagnosed with a sensitivity and specificity of 100%. Evaluation for hemodynamically relevant stenosis was possible in 84% of cases (36 of 43 patent grafts) and yielded a sensitivity of 100% (5 of 5 high-grade stenoses correctly detected) and specificity of 97% (1 false-positive diagnosis of high-grade graft stenosis). The main reasons for impaired ability to evaluate the scans were breathing artifacts and misplacement of the imaging volume, causing parts of the bypass grafts to be cut off. EBT permits noninvasive determination of bypass graft occlusion and relevant stenosis with high accuracy.

The value of contrast-enhanced electron beam tomography (EBT) and 3-dimensional reconstruction for the detection of bypass graft occlusion and stenosis was assessed in 25 patients. Compared with invasive angiography in a blinded fashion, EBT permitted the detection of bypass graft occlusion with 100% accuracy (13 of 13) and visualization of high-grade stenoses with a sensitivity of 100% (5 of 5) and specificity of 97%.

Le texte complet de cet article est disponible en PDF.

Plan


© 1997  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 79 - N° 7

P. 856-861 - avril 1997 Retour au numéro
Article précédent Article précédent
  • Usefulness of Serial Radionuclide Angiography in Predicting Cardiac Death After Coronary Artery Bypass Grafting and Comparison With Clinical and Cardiac Catheterization Data
  • Salvador Borges-Neto, Leslee J Shaw, Karen Kesler, Timothy Sell, Eric D Peterson, R.Edward Coleman, Robert H Jones
| Article suivant Article suivant
  • Further ST Elevation at Reperfusion by Direct Percutaneous Transluminal Coronary Angioplasty Predicts Poor Recovery of Left Ventricular Systolic Function in Anterior Wall AMI
  • Nobuhiko Kobayashi, Nobuhiro Ohmura, Ikuko Nakada, Takanori Yasu, Hisakazu Iwanaka, Norifumi Kubo, Takaaki Katsuki, Mikihisa Fujii, Toshio Yaginuma, Muneyasu Saito

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.