S'abonner

Improved Specificity of Transesophageal Dobutamine Stress Echocardiography Compared to Standard Tests for Evaluation of Coronary Artery Disease in Women Presenting With Chest Pain - 10/09/11

Doi : 10.1016/S0002-9149(97)00702-9 
Joy M Laurienzo A, Richard O Cannon A, Arshed A Quyyumi A, Vasken Dilsizian A, Julio A Panza A,
A Cardiology Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA. 

*Julio A. Panza, MD, National Institutes of Health, Building 10, Room 7B-15, Bethesda, Maryland 20892.

Abstract

The detection of coronary artery disease (CAD) by noninvasive methods has been hindered in women by the high rate of false–positive results. To determine the feasibility and accuracy of transesophageal dobutamine stress echocardiography for identification of CAD in women, we studied 84 patients (age 51 ± 11 years) who underwent symptom-limited exercise treadmill testing, exercise thallium-201 scintigraphy, and coronary angiography for evaluation of anginal chest pain. Of the 84 patients, 62 had normal coronary arteries or nonsignificant coronary lesions, and 22 had significant stenosis of ≥1 major coronary artery. During treadmill exercise, repolarization changes were observed in 16 of 21 patients with CAD and in 19 of 60 patients with normal coronary arteries. With thallium scintigraphy, a reversible defect was observed in 19 of 22 patients with CAD and in 12 of 60 patients with normal coronary arteries. Regional wall motion abnormalities during dobutamine infusion developed in 18 of 22 patients with CAD and in none of the 62 patients with normal coronary arteries. All 3 tests had similar sensitivity for detection of CAD (76% for exercise treadmill test, 86% for thallium scintigraphy, and 82% for transesophageal dobutamine stress echocardiography). However, transesophageal dobutamine stress echocardiography had significantly higher specificity than the other 2 tests (100% vs 68% for exercise treadmill test and 80% for thallium scintigraphy; p = 0.0001). Thus, transesophageal dobutamine stress echocardiography is accurate for evaluation of CAD among women presenting with chest pain; its use should be considered when more conventional tests are equivocal or technically suboptimal.

Le texte complet de cet article est disponible en PDF.

Plan


© 1997  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 80 - N° 11

P. 1402-1407 - décembre 1997 Retour au numéro
Article précédent Article précédent
  • Prognostic Significance of Myocardial Ischemia Detected by Ambulatory Electrocardiography, Exercise Treadmill Testing, and Electrocardiogram at Rest to Predict Cardiac Events by One Year (The Asymptomatic Cardiac Ischemia Pilot [ACIP] Study)
  • Peter H. Stone, Bernard R. Chaitman, Sandra Forman, Thomas C. Andrews, Vera Bittner, Martial G. Bourassa, Richard F. Davies, John E. Deanfield, William Frishman, A.David Goldberg, Gail MacCallum, Pamela Ouyang, Carl J. Pepine, Craig M. Pratt, Barry Sharaf, Richard Steingart, Genell L. Knatterud, George Sopko, C.Richard Conti, for the ACIP Investigatorsfn1fn1A complete list of investigators and centers participating in the ACIP study appears in [19].
| Article suivant Article suivant
  • Variations of Remodeling in Response to Left Main Atherosclerosis Assessed With Intravascular Ultrasound In Vivo
  • Clemens von Birgelen, Sergei G. Airiian, Gary S. Mintz, Wim J. van der Giessen, David P. Foley, Jos R.T.C. Roelandt, Patrick W. Serruys, Pim J. de Feyter

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.