S'abonner

Stethoscopes: A Potential Vector of Infection? - 12/09/11

Doi : 10.1016/S0196-0644(95)70075-7 
Jeffrey S Jones, MD, FACEP, David Hoerle, MD, Robert Riekse, MS

Abstract

Study objectives: To survey emergency care providers about their stethoscope-cleaning measures and to determine the correlation between these measures and the extent of Staphylococcus carriage. Design: Prospective cross-sectional analysis. Setting: University-affiliated community hospital ED. Participants: One hundred fifty health care providers, comprising emergency medicine house staff and attending physicians (n=50), ED nurses (n=50), and prehospital personnel working in Kent County, Michigan (n=50). Interventions: Providers were asked how often they cleaned their stethoscopes and which cleaning agents were used. We then cultured each stethoscope by pressing the diaphragm on mannitol agar and incubating the culture aerobically for 48 hours. Staphylococcus aureus was identified by means of standard measures. We examined the effects of different cleaning agents on 24 stethoscopes. The numbers of colony-forming units (CFUs) before and after cleaning with alcohol, nonionic detergent, and antiseptic soap were noted. Results: Overall, 48% of health care providers (74 of 150) cleaned their stethoscopes daily or weekly, 37% monthly, and 7% yearly; and 7% had never cleaned their stethoscopes. No significant differences were found in the hygiene routines of the three groups of providers surveyed. Use of an alcohol swab was the preferred method of cleaning. One hundred thirty-three stethoscopes (89%) grew staphylococci; 25 (19%) yielded S aureus . Mean staphylococcal bacterial counts (±SD) were 52±78 CFUs per stethoscope among physicians, 46±92 CFUs among emergency medical service personnel, and 13±21 CFUs from the nursing staff (ANOVA, P =.01). Cleaning the stethoscope diaphragm resulted in immediate reduction in the bacterial count: by 94% with alcohol swabs, 90% with nonionic detergent, and 75% with antiseptic soap. Conclusion: Our results confirm that stethoscopes used in emergency practice are often contaminated with staphylococci and are therefore a potential vector of infection. This contamination is greatly reduced by frequent cleaning with alcohol or nonionic detergent. [Jones JS, Hoerle D, Riekse R: Stethoscopes: A potential vector of infection? Ann Emerg Med September 1995;26;296-299.]

Le texte complet de cet article est disponible en PDF.

Plan


 Department of Emergency Medicine, Butterworth Hospital, Michigan State University College of Human Medicine, Grand Rapids, Michigan.
★★ Address for reprints: Jeffrey S Jones, MD, FACEP, Department of Emergency Medicine, 100 Michigan Avenue Northeast, Grand Rapids, Michigan 49503, 616-776-1973, Fax 616-732-3730
 Reprint no. 47/1/66638


© 1995  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 3

P. 296-299 - septembre 1995 Retour au numéro
Article précédent Article précédent
  • Delayed Recognition and Infection Control for Tuberculosis Patients in the Emergency Department
  • Gregory J Moran, Frances McCabe, Marshall T Morgan, David A Talan
| Article suivant Article suivant
  • Decay in Quality of Closed-Chest Compressions Over Time
  • David Hightower, Stephen H Thomas, C.Keith Stone, Kathleen Dunn, Juan A March

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.