Summary

Introduction

The aim of this study is to analyze the long-term results and possible complications of the Grammont reverse shoulder prosthesis in the management of recent trauma in the elderly patient.

Patients and methods

Two male and 33 female patients of mean age 75 years (range, 58 to 92), operated on for 24 fractures and eleven facture-dislocations, involving the right side in 11 cases and the left side in 24 cases, were included in a retrospective study and were clinically and radiographically evaluated at a mean follow-up ranging from 1 to 17 years.

Results

Eight complications occurred in eight patients (23%): two complex regional pain syndromes, four dislocations, one deep infection and one aseptic loosening of the metaglene. Six patients (17%) had to be reoperated on, without prosthetic replacement in four cases and with revision of their shoulder implant in two. The mean Constant score decreased from 55 to 53 between one postoperative year and last follow-up since patients complained of increased pain and strength loss. This score was 69% of that of the contralateral shoulder. The adjusted Constant score was 68%. Only 58% of the patients were “satisfied” or “very satisfied” with the treatment due to limited shoulder rotations thus preventing proper eating, dressing and body hygiene habits when injury involved the dominant side. Two cases of complete lucent lines surrounding the glenoid component were observed at four and eight postoperative years respectively, a stable inferior bony spur was noted in 14 cases at a mean follow-up of 2.5 years with no functional effects, 20 cases of scapular notching having occurred within two-year follow-up were identified, 10 of which associated with bone resorption and medial proximal humeral lucent lines at the bone-cement interface. The extent of scapular notching progressed with the length of follow-up. Forty-nine percent of the radiographic images were considered abnormal and appeared within seven-year follow-up in 60% of the cases. Clinical and radiographic data comparison revealed a decrease in the Constant score regarding pain, activity, strength and active elevation when scapular notching was associated with abnormal humeral radiographic images.

Discussion

Despite one single case of aseptic loosening of the metaglene at 12-year follow-up, the results of our series are clinically disappointing and radiographically worrying associated with a substantial rate of complications and reopperations. The long-term functional outcome is far from being identical to the pre-trauma clinical status with a potential evolution toward loss of autonomy when the dominant side is affected. New prosthetic design characteristics and surgical technique improvements should be implemented to improve shoulder adduction but also rotations while preventing the occurrence of scapular notching. In the light of these results, we cannot validate the concept of primary reverse shoulder arthroplasty in the management of recent trauma of the proximal humerus.

Level of evidence

Level IV. Retrospective study.

Le texte complet de cet article est disponible en PDF.

Keywords : Shoulder, Fracture, Reverse Arthroplasty


Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 97 - N° 6

P. 583-589 - octobre 2011 Retour au numéro
Article précédent Article précédent
  • Influence of surgical approach on functional outcome in reverse shoulder arthroplasty
  • A. Lädermann, A. Lubbeke, P. Collin, T.B. Edwards, F. Sirveaux, G. Walch
| Article suivant Article suivant
  • Residual inferior glenohumeral instability after arthroscopic Bankart repair: Radiological evaluation and functional results
  • A. Meyer, S. Klouche, T. Bauer, B. Rousselin, P. Hardy

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.