Fouille d’images multi-instance et multi-résolution appliquée au dépistage de la rétinopathie diabétique - 01/12/11

Multiple-instance and multi-resolution image mining for diabetic retinopathy screening

Doi : 10.1016/j.irbm.2011.09.010 
G. Quellec a, , b , M.D. Abràmoff c, d, G. Cazuguel a, b, M. Lamard a, e, B. Cochener a, e, C. Roux a, b
a U650, Inserm, IFR 148 ScInBioS, 29200 Brest, France 
b Département ITI, Institut telecom, telecom Bretagne, UEB, 29200 Brest, France 
c Department of ophthalmology and visual sciences, university of Iowa, Iowa City, IA 52242, États-Unis 
d Department of electrical and computer engineering, university of Iowa, Iowa City, IA 52242, États-Unis 
e Université de Bretagne Occidentale, 29200 Brest, France 

Auteur correspondant. Laboratoire de traitement de l’information médicale, CHU Morvan, bâtiment 2bis (I3S), 5, avenue Foch, 29609 Brest cedex, France.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 9
Iconographies 6
Vidéos 0
Autres 0

Résumé

Objectifs

Des études récentes ont montré l’intérêt potentiel de l’interprétation automatique des photographies de fond d’œil pour le dépistage de la rétinopathie diabétique (RD). Une nouvelle approche est proposée pour résoudre deux problèmes communs à tous les systèmes de dépistage automatique de la RD : la mesure de la qualité des images et la détection des lésions complexes ou rares.

Patients et méthodes

Une nouvelle caractérisation d’images, basée sur la transformée en ondelettes, est proposée pour rechercher les anomalies dans les images à différentes résolutions (la notion de normalité étant spécifique à chaque problème). L’algorithme de recherche repose sur un apprentissage multi-instance : des experts indiquent les examens présentant des anomalies, sans indiquer leur localisation dans les images et l’algorithme apprend à détecter ces anomalies automatiquement. L’algorithme a été validé sur une base de données constituée de 25 702 examens de dépistage, soit au total 107 799 images.

Résultats

L’algorithme est capable de détecter les examens dont la qualité des images est insuffisante avec une aire Az=0,907 sous la courbe ROC. Il permet en outre de détecter les patients atteints de RD proliférante avec une aire Az=0,792 et de les différencier des patients atteints de RD non proliférante avec une aire Az=0,819.

Discussion

Cette approche, couplée avec une détection automatique des premiers signes de la RD (des lésions fréquentes de petites tailles), permettra un dépistage automatique plus robuste de la RD ainsi que des autres pathologies rencontrées dans les centres de dépistage.

Le texte complet de cet article est disponible en PDF.

Abstract

Objectives

Automated analysis of eye fundus images has recently proven useful for diabetic retinopathy (DR) screening. A novel image analysis framework is introduced in this paper for solving two remaining problems shared by all automated DR screening systems: image quality assessment and complex or rare lesion detection.

Patients and methods

A new wavelet-based image description is introduced: given a problem-specific definition of abnormality, this image description is used to search for abnormal areas in images at different resolutions. The proposed search algorithm is based on multiple-instance learning: experts indicate examination records presenting abnormalities, without locating these abnormalities in images, and the algorithm learns to detect them automatically. This algorithm has assessed on a dataset of 25,702 screening examination records, consisting of 107,799 images altogether.

Results

The algorithm was able to detect examination records containing low quality images with an area Az=0.907 under the ROC curve. It was also able to detect patients with proliferative DR with an area Az=0.792, as well as differentiating them from non proliferative DR patients with an area Az=0.819.

Discussion

Used jointly with the automated detection of the early signs of DR (small, frequent lesions), the proposed approach should increase the robustness of automated detection of DR and of the other pathologies seen in screening centers.

Le texte complet de cet article est disponible en PDF.

Plan


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 32 - N° 6

P. 342-350 - décembre 2011 Retour au numéro
Article précédent Article précédent
  • Analyse théorique et expérimentale de la diffusion de la lumière générée par une diode électroluminescente dans des répliques tissulaires
  • J.-Y. Le Pommellec, J.-P. L’Huillier
| Article suivant Article suivant
  • Nouvelle méthode de segmentation des volumes d’intérêt en TEP : utilisation de la théorie des possibilités
  • A.-S. Dewalle-Vignion, N. Makni, N. Betrouni, D. Huglo, S. Stute, I. Buvat, M. Vermandel

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.