S'abonner

Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists - 09/02/12

Doi : 10.1016/j.clinre.2011.09.009 
Naoki Hosoe a, Jean-François Rey c, Hiroyuki Imaeda d, Rieko Bessho b, Riko Ichikawa b, Yosuke Ida b, Makoto Naganuma e, Takanori Kanai b, Toshifumi Hibi b, Haruhiko Ogata a,
a Center for Diagnostic and Therapeutic Endoscopy, School of Medicine, Keio University, 35 Shinanomachi, Shinjuku, Tokyo 160-8582, Japan 
b Division of Gastroenterology and Hepatology, Department of Internal Medicine, School of Medicine, Keio University, Tokyo, Japan 
c Institut Arnault Tzanck, Saint-Laurent-du-Var, France 
d Department of General Internal Medicine, Saitama Medical University, Saitama, Japan 
e Department of Gastroenterology, School of Medicine, Tokyo Medical and Dental University, Tokyo, Japan 

Corresponding author. Tel.: +81 3 3353 1211; fax: +81 3 3357 2778.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

pages 6
Iconographies 5
Vidéos 0
Autres 0

Summary

Background and objective

Capsule endoscopy (CE) is a comfortable for the patients; however, CE review is time-consuming. The aim of this study was (1) to evaluate the effectiveness of the CE software in reducing the CE reading time and the number of false negatives by beginners, and (2) to determine the learning curve for reading CE images.

Methods

Capsule endoscopic images were captured by Pillcam SB (Given Imaging Ltd, Tokyo, Japan), and analyzed using the proprietary RAPID 5 software. Comparison of CE reading using different software modes: manual mode, automatic mode, and QuickView (QV) mode. Three trainee endoscopists participated as CE readers. Each participant watched CE videos in which positive findings had been predefined by trained endoscopists. Each participant read the same CE record by using one of three different software modes. These were blinded on clinical history of patients. CE reading time was recorded, and the number of false negatives was counted. Each trainee endoscopist read a total of 45 CE videos, in five steps divided into nine videos per step.

Results

There was no significant reader associated difference between the results for the different modes. The QV software did miss some positive findings. Therefore, the total number of instances of FN by the software plus the reader in the QV mode was significantly higher than the others. The reading times in the automatic mode and the QV mode were significantly shorter than that in the manual mode. After the second step, the number of instances of false negatives significantly decreased.

Conclusions

CE software is useful for reducing the reading time. Experience of approximately 20 CE readings can be considered as the first step to becoming an expert.

Le texte complet de cet article est disponible en PDF.

Plan


 N.H. designed this study, analyzed the data, and wrote the paper. JF. R., H.I., T.K. edited the paper, and supervised the study. R.B., R.I., Y.I. participated in the study as CE reader. M.N. judged the result. H.O. and T.H. helped conceive and supervise the study.


© 2011  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 36 - N° 1

P. 66-71 - février 2012 Retour au numéro
Article précédent Article précédent
  • Liver denervation increases the levels of serum triglyceride and cholesterol via increases in the rate of VLDL secretion
  • Mehdi Rasouli, Mahboobeh Mosavi-Mehr, Hanieh Tahmouri
| Article suivant Article suivant
  • Noise-induced duodenal lesions: A light and electron microscopy study of the lesions of the rat duodenal mucosa exposed to low frequency noise
  • J. Fonseca, J. Martins dos Santos, P. Oliveira, N. Laranjeira, N.A.A. Castelo Branco

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’achat d’article à l’unité est indisponible à l’heure actuelle.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.