Comparison of Left Ventricular Outflow Geometry and Aortic Valve Area in Patients With Aortic Stenosis by 2-Dimensional Versus 3-Dimensional Echocardiography - 12/05/12

Doi : 10.1016/j.amjcard.2012.01.391 
Takeji Saitoh, MD a, Maiko Shiota, MD b, Masaki Izumo, MD a, Swaminatha V. Gurudevan, MD a, Kirsten Tolstrup, MD a, Robert J. Siegel, MD a, Takahiro Shiota, MD a,
a Cedars-Sinai Heart Institute, Cedars-Sinai Medical Center, and UCLA, Los Angeles, California 
b Stanford University Medical Center, Stanford, California 

Corresponding author: Tel: (310) 423-8571; fax: (310) 423-6889

Résumé

The present study sought to elucidate the geometry of the left ventricular outflow tract (LVOT) in patients with aortic stenosis and its effect on the accuracy of the continuity equation-based aortic valve area (AVA) estimation. Real-time 3-dimensional transesophageal echocardiography (RT3D-TEE) provides high-resolution images of LVOT in patients with aortic stenosis. Thus, AVA is derived reliably with the continuity equation. Forty patients with aortic stenosis who underwent 2-dimensional transthoracic echocardiography (2D-TTE), 2-dimensional transesophageal echocardiography (2D-TEE), and RT3D-TEE were studied. In 2D-TTE and 2D-TEE, the LVOT areas were calculated as π × (LVOT dimension/2)2. In RT3D-TEE, the LVOT areas and ellipticity ([diameter of the anteroposterior axis]/[diameter of the medial-lateral axis]) were evaluated by planimetry. The AVA is then determined using planimetry and the continuity equation method. LVOT shape was found to be elliptical (ellipticity of 0.80 ± 0.08). Accordingly, the LVOT areas measured by 2D-TTE (median 3.7 cm2, interquartile range 3.1 to 4.1) and 2D-TEE (median 3.7 cm2, interquartile range 3.1 to 4.0) were smaller than those by 3D-TEE (median 4.6 cm2, interquartile range 3.9 to 5.3; p <0.05 vs both 2D-TTE and 2D-TEE). RT3D-TEE yielded a larger continuity equation-based AVA (median 1.0 cm2, interquartile range 0.79 to 1.3, p <0.05 vs both 2D-TTE and 2D-TEE) than 2D-TTE (median 0.77 cm2, interquartile range 0.64 to 0.94) and 2D-TEE (median 0.76 cm2, interquartile range 0.62 to 0.95). Additionally, the continuity equation-based AVA by RT3D-TEE was consistent with the planimetry method. In conclusion, RT3D-TEE might allow more accurate evaluation of the elliptical LVOT geometry and continuity equation-based AVA in patients with aortic stenosis than 2D-TTE and 2D-TEE.

Le texte complet de cet article est disponible en PDF.

Plan


 Drs. Siegel and Shiota are members of Philips Medical Systems Speaker Bureau (Bothell, Washington).


© 2012  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 109 - N° 11

P. 1626-1631 - juin 2012 Retour au numéro
Article précédent Article précédent
  • Relation of Dosing of the Renin–Angiotensin System Inhibitors After Cardiac Resynchronization Therapy to Long-Term Prognosis
  • Lilian Mantziari, Kaushik Guha, Zohya Khalique, Theresa McDonagh, Rakesh Sharma
| Article suivant Article suivant
  • Frequency of Congenitally Bicuspid Aortic Valves in Patients ≥80 Years of Age Undergoing Aortic Valve Replacement for Aortic Stenosis (With or Without Aortic Regurgitation) and Implications for Transcatheter Aortic Valve Implantation
  • William Clifford Roberts, Kaitlin Georgeanne Janning, Jong Mi Ko, Giovanni Filardo, Gregory John Matter

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.