The learning curve, accuracy, and interobserver agreement of endoscope-based confocal laser endomicroscopy for the differentiation of colorectal lesions - 23/05/12

Doi : 10.1016/j.gie.2012.01.040 
Teaco Kuiper, MD 1, Ralf Kiesslich, MD, PhD 2, Cyriel Ponsioen, MD, PhD 1, Paul Fockens, MD, PhD 1, Evelien Dekker, MD, PhD 1,
1 Department of Gastroenterology and Hepatology, Academic Medical Centre, University of Amsterdam, Amsterdam, the Netherlands 
2 I. Medical Clinic, Johannes Gutenberg University of Mainz, Mainz, Germany 

Reprint requests: Evelien Dekker, MD, PhD, Department of Gastroenterology and Hepatology, Academic Medical Centre, University of Amsterdam, Meibergdreef 9, 1105 AZ Amsterdam, the Netherlands

Résumé

Background

The endoscope-based confocal laser endomicroscopy (eCLE) system allows in vivo imaging of colorectal epithelium. Little is known about the learning curve for accurate interpretation of confocal images acquired with eCLE.

Objective

To determine the learning curve of eCLE, its diagnostic accuracy, and the intra- and interobserver agreement for the differentiation of colorectal lesions.

Design

Post hoc assessment of selected eCLE images.

Setting

Academic centers.

Patients

This study involved colonoscopic images from 47 patients.

Main Outcome Measurements

Learning curve of eCLE, accuracy, and intraobserver and interobserver agreement.

Methods

Three endoscopists received a short introduction to eCLE before evaluating 90 images. Observers assessed all eCLE images by using the Mainz classification. After each set of 30 images, the accuracy of each observer was assessed. The same procedure was repeated 6 months later by using the same set of images.

Limitations

Post hoc assessment.

Results

There were no significant changes between the first set of 30 images and the 2 consecutive sets (P = .08 and P = .180, respectively). The overall accuracy was 85.6%, 95.6%, and 92.2% for each observer. The κ values of the intraobserver agreement were 0.68, 0.84, and 0.77 for each observer. The κ value for interobserver agreement was 0.73 during the first and 0.72 during the second assessment.

Conclusions

Accurate post hoc interpretation of eCLE confocal images can be learned quickly. High diagnostic accuracy was achieved by all 3 observers during the initial stage of the assessment, which remained high thereafter. Intra- and interobserver agreement was substantial for all 3 observers. Future studies should focus on the real-time assessment of eCLE images.

Le texte complet de cet article est disponible en PDF.

Abbreviations : CLE, eCLE, pCLE


Plan


 DISCLOSURE: The following author disclosed financial relationships relevant to this publication: Dr Kiesslich: unrestricted grant, Pentax Europe, and has received instruments for free from Optiscan. The other authors disclosed no financial relationships relevant to this publication.


© 2012  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 75 - N° 6

P. 1211-1217 - juin 2012 Retour au numéro
Article précédent Article précédent
  • Failure to recognize serrated polyposis syndrome in a cohort with large sessile colorectal polyps
  • Krishna C. Vemulapalli, Douglas K. Rex
| Article suivant Article suivant
  • Endoscopic appearance of proximal colorectal neoplasms and potential implications for colonoscopy in cancer prevention
  • Eveline J.A. Rondagh, Mariëlle W.E. Bouwens, Robert G. Riedl, Bjorn Winkens, Rogier de Ridder, Tonya Kaltenbach, Roy M. Soetikno, Ad A.M. Masclee, Silvia Sanduleanu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.