S'abonner

SINGLE-01: a randomized, controlled trial comparing the efficacy and depth of insertion of single- and double-balloon enteroscopy by using a novel method to determine insertion depth - 16/10/12

Doi : 10.1016/j.gie.2012.06.033 
Marios Efthymiou, MBBS, MD, FRACP 1, 2, , Paul V. Desmond, MBBS, MD, FRACP 1, Gregor Brown, MBBS, PhD, FRACP 3, Richard La Nauze, MBBS, FRACP 3, Arthur Kaffes, MBBS, FRACP 4, Tee Joo Chua, MBBS, MRCP 4, Andrew C.F. Taylor, MBBS, MD, FRACP 1
1 Department of Gastroenterology, St. Vincent's Hospital, Melbourne, Victoria, Australia 
2 University of Melbourne, Melbourne, Victoria, Australia 
3 Department of Gastroenterology, The Alfred Hospital, Melbourne, Victoria, Australia 
4 Department of Gastroenterology, Royal Prince Alfred Hospital, Sydney, New South Wales, Australia 

Reprint requests: Marios Efthymiou, MBBS, MD, FRACP, St. Vincent's Hospital, Victoria Parade, Fitzroy 3065, Melbourne, Victoria, Australia

Résumé

Background

Single-balloon enteroscopy (SBE) was introduced as an alternative to double-balloon enteroscopy (DBE) for the investigation and management of small-bowel conditions. To date, there is only 1 randomized, controlled trial comparing SBE and DBE in a Western population.

Objective

To compare the 2 instruments in a Western population to assess for differences in clinical outcomes and insertion depth (ID). A novel method to determine ID by counting folds on withdrawal was used.

Design

Multicenter, randomized, controlled trial.

Setting

University hospitals in Melbourne and Sydney, Australia.

Patients

Patients with suspected or proven small-bowel disease.

Interventions

SBE and DBE.

Main Outcome Measurement

The primary endpoint was diagnostic yield (DY). Secondary endpoints were therapeutic yield (TY), procedure times, and ID. An intention-to-treat analysis was performed.

Results

A total of 116 patients were screened, and 107 patients were enrolled between July 2008 and June 2010, in whom 119 procedures were undertaken (53 SBEs and 66 DBEs). DY was 57% for SBE and 53% for DBE (P = .697). TY was 32% for SBE and 26% for DBE (P = .490). The median enteroscopy times were identical for SBE and DBE at 60 minutes. The mean ID by the fold-counting method for antegrade procedures was 201.1 folds for SBE and 258.6 folds for DBE (P = .046). After multiple comparisons adjustment, this difference did not reach statistical significance. Mean IDs by using the visual estimation method for SBE and DBE were, respectively, 72.1 cm and 75.2 cm (P = .835) for retrograde procedures and 203.8 cm and 234.1 cm (P = .176) for antegrade procedures.

Limitations

Unable to reach target sample size, mostly single-center recruitment, novel method to determine ID, which requires further validation.

Conclusions

SBE has DY, TY, and procedure times similar to those of DBE. There were no statistically significant differences in ID between SBE and DBE. By using the fold-counting method for antegrade procedures, the estimated IDs for SBE and DBE were 201.1 folds versus 258.6 folds (P = .046; P = not significant after adjustment for multiple comparisons). (Clinical trial registration number: ACTRN12609000917235.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : DBE, DY, ID, SBE, TY


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2012  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 76 - N° 5

P. 972-980 - novembre 2012 Retour au numéro
Article précédent Article précédent
  • Comparative analysis of traditional and coiled fiducials implanted during EUS for pancreatic cancer patients receiving stereotactic body radiation therapy
  • Mouen A. Khashab, Katherine J. Kim, Erik J. Tryggestad, Aaron T. Wild, Teboh Roland, Vikesh K. Singh, Anne Marie Lennon, Eun Ji Shin, Mark A. Ziegler, Reem Z. Sharaiha, Marcia Irene Canto, Joseph M. Herman
| Article suivant Article suivant
  • Device-assisted enteroscopy: how deep is deep enteroscopy?
  • Tom G. Moreels

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.