S'abonner

Monitoring uterine activity during labor: a comparison of 3 methods - 21/12/12

Doi : 10.1016/j.ajog.2012.10.873 
Tammy Y. Euliano, MD a, ⁎ , Minh Tam Nguyen, MS b, Shalom Darmanjian, PhD b, Susan P. McGorray, PhD c, Neil Euliano, PhD b, Allison Onkala, MEd/EdS d, Anthony R. Gregg, MD e
a Department of Anesthesiology and Obstetrics and Gynecology, University of Florida College of Medicine, Gainesville, FL 
b Convergent Engineering, Gainesville, FL 
c College of Public Health & Health Professions, University of Florida College of Medicine, Gainesville, FL 
d Department of Anesthesiology, University of Florida College of Medicine, Gainesville, FL 
e Department of Obstetrics and Gynecology, University of Florida College of Medicine, Gainesville, FL 

Reprints: Tammy Y. Euliano, MD, Department of Anesthesiology, PO Box 100254, Gainesville, FL 32610-0254

Résumé

Objective

Tocodynamometry (Toco; strain gauge technology) provides contraction frequency and approximate duration of labor contractions but suffers frequent signal dropout, necessitating repositioning by a nurse, and may fail in obese patients. The alternative invasive intrauterine pressure catheter (IUPC) is more reliable and adds contraction pressure information but requires ruptured membranes and introduces small risks of infection and abruption. Electrohysterography (EHG) reports the electrical activity of the uterus through electrodes placed on the maternal abdomen. This study compared all 3 methods of contraction detection simultaneously in laboring women.

Study Design

Upon consent, laboring women were monitored simultaneously with Toco, EHG, and IUPC. Contraction curves were generated in real-time for the EHG, and all 3 curves were stored electronically. A contraction detection algorithm was used to compare frequency and timing between methods. Seventy-three subjects were enrolled in the study; 14 were excluded due to hardware failure of 1 or more of the devices (n = 12) or inadequate data collection duration (n = 2).

Results

In comparison with the gold-standard IUPC, EHG performed significantly better than Toco with regard to the Contractions Consistency Index (CCI). The mean CCI for EHG was 0.88 ± 0.17 compared with 0.69 ± 0.27 for Toco (P < .0001). In contrast to Toco, EHG was not significantly affected by obesity.

Conclusion

Toco does not correlate well with the gold-standard IUPC and fails more frequently in obese patients. EHG provides a reliable noninvasive alternative, regardless of body habitus.

Le texte complet de cet article est disponible en PDF.

Key words : electrohysterography, electronic fetal monitoring, uterine activity monitoring


Plan


 This material is based on work supported by National Institutes of Health grant number R44 HD056606.
 N.E. is president and M.T.N. and S.D. are employees of Convergent Engineering. T.Y.E. owns no stock or holds any position in the company but is married to N.E. and listed on patents filed for some of the technology described in this paper. The other authors report no conflict of interest.
 Cite this article as: Euliano TY, Nguyen MT, Darmanjian S, et al. Monitoring uterine activity during labor: a comparison of 3 methods. Am J Obstet Gynecol 2013;208:66.e1-6.


© 2013  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 208 - N° 1

P. 66.e1-66.e6 - janvier 2013 Retour au numéro
Article précédent Article précédent
  • Maternal autoantibody levels in congenital heart block and potential prophylaxis with antiinflammatory agents
  • Robert D. Tunks, Megan E.B. Clowse, Stephen G. Miller, Leo R. Brancazio, Piers C.A. Barker
| Article suivant Article suivant
  • Fibroid tumors are not a risk factor for adverse outcomes in twin pregnancies
  • Molly J. Stout, Anthony O. Odibo, Anthony L. Shanks, Ryan E. Longman, George A. Macones, Alison G. Cahill

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.