S'abonner

Laparoendoscopic Single Site (LESS) In Vivo Suturing Using a Magnetic Anchoring and Guidance System (MAGS) Camera in a Porcine Model: Impact on Ergonomics and Workload - 27/12/12

Doi : 10.1016/j.urology.2012.09.018 
Gang Yin a, b, Woong Kyu Han a, Stephen Faddegon a, Yung Khan Tan a, Zhuo-Wei Liu a, Ephrem O. Olweny a, Daniel J. Scott c, Jeffrey A. Cadeddu a,
a Department of Urology, University of Texas Southwestern Medical Center, Dallas, Texas 
b Department of Urology, Qilu Hospital, Shandong University, Jinan, China 
c Department of Surgery, University of Texas Southwestern Medical Center, Dallas, Texas 

Reprint requests: Jeffrey A. Cadeddu, M.D., Department of Urology, University of Texas Southwestern Medical Center, 5323 Harry Hines Blvd, Dallas, TX 75390-9110.

Abstract

Objective

To compare the ergonomics and workload of the surgeon during single-site suturing while using the magnetic anchoring and guidance system (MAGS) camera vs a conventional laparoscope.

Methods

Seven urologic surgeons were enrolled and divided into an expert group (n = 2) and a novice group (n = 5) according to their laparoendoscopic single-site (LESS) experience. Each surgeon performed 2 conventional LESS and 2 MAGS camera-assisted LESS vesicostomy closures in a porcine model. A Likert scale (scoring 1-5) questionnaire assessing workload, ergonomics, technical difficulty, visualization, and needle handling, as well as a validated National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire were used to evaluate the tasks and workloads.

Results

MAGS LESS suturing was universally favored by expert and novice surgeons compared with conventional LESS in workload (3.4 vs 4.2), ergonomics (3.4 vs 4.4), technical challenge (3.3 vs 4.3), visualization (2.4 vs 3.3), and needle handling (3.1 vs 3.9 respectively; P <.05 for all categories). Surgeon NASA-TLX assessments found MAGS LESS suturing significantly decreased the workload in physical demand (P = .004), temporal demand (P = .017), and effort (P = .006). External instrument clashing was significantly reduced in MAGS LESS suturing (P <.001). The total operative time of MAGS LESS suturing was comparable to that of conventional LESS (P = .89).

Conclusion

MAGS camera technology significantly decreased surgeon workload and improved ergonomics. Nevertheless, LESS suturing and knot tying remains a challenging task that requires training, regardless of which camera is used.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosure: The authors declare that they have no relevant financial interests.
 Funding Support: Prior support for MAGS research provided by Ethicon Endosurgery. No support or role in this study design, data collection or analysis, manuscript preparation.


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 81 - N° 1

P. 80-84 - janvier 2013 Retour au numéro
Article précédent Article précédent
  • Does Mechanical Bowel Preparation Improve Quality of Laparoscopic Nephrectomy? Propensity Score-matched Analysis in Japanese Series
  • Toru Sugihara, Hideo Yasunaga, Hiromasa Horiguchi, Tetsuya Fujimura, Hiroaki Nishimatsu, Kazuhiko Ohe, Shinya Matsuda, Kiyohide Fushimi, Michael W. Kattan, Yukio Homma
| Article suivant Article suivant
  • Retroperitoneoscopic Adrenalectomy: Comparison of Retrograde and Antegrade Approach Among a Series of 279 Cases
  • Eric Huyghe, Guillaume Crenn, Béatrice Duly-Bouhanick, Delphine Vezzosi, Antoine Bennet, Fouad Atallah, Michel Mazerolles, Ali Salloum, Matthieu Thoulouzan, Boris Delaunay, Solange Grunenwald, Jacques Amar, Pierre Plante, Bernard Chamontin, Philippe Caron, Michel Soulié

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.