S'abonner

Reduction in operator radiation exposure during transradial catheterization and intervention using a simple lead drape - 01/03/13

Doi : 10.1016/j.ahj.2012.10.002 
Ali F. Iqtidar, MD, Cathy Jeon, MD, MSc, Richard Rothman, MD, Randall Snead, RRT, Christopher T. Pyne, MD
 Cardiac Catheterization Laboratory, Section of Interventional Cardiology, Lahey Clinic, Burlington, MA 

Reprint requests: Christopher T. Pyne, MD, Cardiac Catheterization Laboratory, Lahey Clinic Medical Center 41 Mall Road, Burlington, MA 01805.

Résumé

Background

Transradial access for cardiac catheterization and intervention is a recognized method for reducing complications and improving patient comfort. However, there are concerns over possible increased operator radiation exposure. We tested the hypothesis that a simple lead drape would reduce operator exposure in transradial procedures.

Methods

Patients undergoing either diagnostic or interventional procedures using transradial access were assigned in an alternating manner to the use of a 0.5-mm lead apron across the patient's abdomen in addition to standard operator protection. Patients were divided into 4 groups: (left enhanced shielding vs left standard shielding; right enhanced shielding vs right standard shielding). Dosimeters were taped to the primary and secondary operators' left wrist and outside the thyroid guard. The operator exposure was measured for each site on every case in centigray.

Results

In standard shielded patients, there was no increase in operator exposure between the left and right approach patients at any measurement site. Measured exposure was reduced with enhanced shielding at all dosimeter sites except the secondary operator's collar (both left and right) and the primary operator's collar from the right. There was no significant difference in fluoroscopy, air kerma, or dose area product between standard and enhanced shielded patients.

Conclusions

The use of a lead drape reduces the rate of operator radiation exposure at multiple measurement sites. Use of the left radial approach was not associated with an increase in operator exposure compared with the right radial approach.

Le texte complet de cet article est disponible en PDF.

Plan


© 2013  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 165 - N° 3

P. 293-298 - mars 2013 Retour au numéro
Article précédent Article précédent
  • Radiation exposure during coronary angiography via transradial or transfemoral approaches when performed by experienced operators
  • Binita Shah, Sripal Bangalore, Frederick Feit, Gregory Fernandez, John Coppola, Michael J. Attubato, James Slater
| Article suivant Article suivant
  • Impact of a dedicated “radial lounge” for percutaneous coronary procedures on same-day discharge rates and bed utilization
  • Shireen Brewster, Kapil Khimdas, Noel Cleary, Angela Penswick, Samantha Cliffe, Roshan Weerackody, Andrew Wragg, Martin T. Rothman, R. Andrew Archbold

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.