Batteryless implantable dual-sensor capsule for esophageal reflux monitoring - 19/03/13

Doi : 10.1016/j.gie.2012.10.029 
Hung Cao, PhD 1, Smitha Rao, PhD 2, Shou-jiang Tang, MD 3, , Harry F. Tibbals, PhD 4, Stuart Spechler, MD 5, J.-C. Chiao, PhD 1, 5
1 Electrical Engineering Department, The University of Texas at Arlington, Arlington, Texas, USA 
2 Med-Worx, Grand Prairie, Texas, USA 
3 Department of Digestive Diseases, University of Mississippi Medical Center, Jackson, Mississippi, USA 
4 Materials Science and Engineering Department, The University of Texas at Arlington, Arlington, Texas, USA 
5 Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, Texas, USA 

Reprint requests: Shou-jiang Tang, MD, Division of Digestive Diseases, Department of Internal Medicine, 2500 North State Street, Jackson, MS 39216

Résumé

Background

Chronic GERD affects approximately 15% of adults in the United States and is one of the most prevalent clinical conditions involving the GI tract. The commercial tools for monitoring GERD include multichannel intraluminal impedance (MII) probes and pH-sensing capsules. However, MII probes cause discomfort, which alters patients' regular activities, whereas the pH-sensing capsule lacks the ability to detect weak or nonacid episodes, misses reflux episodes with similar pH values, and has a limited sampling rate and battery life.

Objective

To develop and test an implantable batteryless dual-sensor capsule that can be used to diagnose and monitor GERD.

Design

The implanted capsule is wirelessly powered by an external device. Simulated reflux episodes were created in 3 live porcine models. Impedance and pH data were continuously measured and recorded.

Intervention

The implant capsule was placed in the esophagus along with a commercial pH-sensing capsule for comparison.

Main Outcome Measurements

Precise impedance and pH readouts were obtained and compared with those from a commercial pH-sensing capsule.

Results

The wireless energy supplied by the external unit was strong enough to power the implant. The pH sensor accurately measured pH levels and the impedance sensor precisely located the reflux episodes.

Limitation

Simulated reflux events in a pig model.

Conclusion

Our wireless sensors are reliable in operation and provide accurate assessment of simulated reflux episodes. The entire device can potentially be used to diagnose and monitor GERD.

Le texte complet de cet article est disponible en PDF.

Abbreviations : BEST, MII, NG


Plan


 DISCLOSURE: Smitha Rao was employed by Med-Worx. University of Texas at Arlington received a subcontract of a National Science Foundation SBIR grant from Med-Worx to J.-C. Chiao's research group for device design and telemetry characterization. The other authors disclosed no financial relationships relevant to this publication. Shou-jiang Tang, H. F. Tibbals, Stuart Spechler, and J.-C. Chiao were listed as the co-inventors of the reported technology. Certain aspects of this technology have been covered in intellectual property filed by the University of Texas Arlington and UT Southwestern.


© 2013  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 77 - N° 4

P. 649-653 - avril 2013 Retour au numéro
Article précédent Article précédent
  • Novel technique for submucosal tunneling and endoscopic resection of submucosal tumors (with video)
  • Mouen A. Khashab, Payal Saxena, Ali Kord Valeshabad, Yamile Haito Chavez, Faming Zhang, Venkata Akshintala, Gerard Aguila, Haruhiro Inoue, Pankaj J. Pasricha, Horst Neuhaus, Anthony N. Kalloo
| Article suivant Article suivant
  • A new instrument for endoscopic submucosal dissection (with videos)
  • Alexander Meining, Armin Schneider, Daniel Roppenecker, Tim Lüth

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.