S'abonner

Uncorrected Binocular Performance After Biaspheric Ablation Profile for Presbyopic Corneal Treatment Using AMARIS with the PresbyMAX Module - 20/03/13

Doi : 10.1016/j.ajo.2012.10.023 
Pierre Baudu a, , Franck Penin b, Samuel Arba Mosquera c
a Clinique Avicennne, Le Port, Ile de la Réunion, France 
b Schwind France Eye-Tech-Solutions, Habsheim, France 
c Schwind Eye-Tech-Solutions, Kleinostheim, Germany 

Inquiries to Pierre Baudu, Clinique Avicenne, 4 allée Avicenne, 97420 Le Port, Ile de la Réunion, France

Abstract

Purpose

To analyze the uncorrected binocular performance after biaspheric multifocal central presbyopic laser in situ keratomileusis treatments.

Design

Retrospective, interventional case series.

Methods

setting. Private clinical practice. patient or study population. Three hundred fifty-eight presbyopic patients (43% males, 82 myopic), bilaterally treated, suitable for laser in situ keratomileusis, with monocular corrected distance visual acuity of 20/32 or better. intervention or observation procedure(s). PresbyMAX (Schwind Eye-Tech-Solutions GmbH and Co) biaspheric multifocal ablation. main outcome measures. Binocular uncorrected distance visual acuity (UDVA) and near visual acuity (UNVA) after surgery and their changes compared with corrected distance visual acuity and corrected near visual acuity before surgery.

Results

At 6 months, 76% of patients achieved a UDVA of 0.1 logarithm of the minimal angle of resolution (logMAR; Snellen equivalent, 20/25) or better, 91% of patients obtained a UNVA of 0.1 logarithmic of the reading acuity determination (logRAD) (p3) or better, and 99% of patients were within 1 diopter of defocus. Postoperative mean spherical equivalent was −0.17 ± 0.34 diopter. Ninety-six percent of patients achieved a UDVA of 0.2 logMAR (Snellen equivalent, 20/32) or better and a UNVA of 0.2 logRAD (p4) or better. Mean binocular corrected distance visual acuity degraded from 0.00 ± 0.01 logMAR (Snellen equivalent, 20/20) to a UDVA of 0.09 ± 0.07 logMAR (Snellen equivalent, 20/25). Mean binocular corrected near visual acuity degraded from 0.02 ± 0.01 logRAD (p2) to a UNVA of 0.07 ± 0.07 logRAD (p2).

Conclusions

Although optically the results are predictable, approximately 17% of the patients did not obtain objectively successful outcomes. In presbyopic patients without symptomatic cataracts, but with refractive errors, the PresbyMAX will decrease the presbyopic symptoms and correct far distance refraction in the same treatment, offering spectacle-free vision in daily life in most of the patients. Further investigation is necessary to evaluate the overall benefit of this procedure.

Le texte complet de cet article est disponible en PDF.

Plan


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 155 - N° 4

P. 636 - avril 2013 Retour au numéro
Article précédent Article précédent
  • Objective Assessment of Crystalline Lens Opacity Level by Measuring Ocular Light Scattering With a Double-Pass System
  • Florence Cabot, Alain Saad, Colm McAlinden, Nour Maya Haddad, Alice Grise-Dulac, Damien Gatinel
| Article suivant Article suivant
  • Comparison of Retention Rates and Complications of 2 Different Types of Silicon Lacrimal Punctal Plugs in the Treatment of Dry Eye Disease
  • Minako Kaido, Reiko Ishida, Murat Dogru, Kazuo Tsubota

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.