Résumé

Objective

To determine the relation between thrombin generation (measured by thrombin-antithrombin [TAT] complexes) early in pregnancy and subsequent preterm delivery.

Study Design

Select cohort of 731 women undergoing indicated second trimester amniocentesis prospectively followed to delivery. Primary outcome was preterm delivery. TAT levels were examined continuously and categorized by quartiles. Multivariable techniques were applied to adjust for potential confounders. Receiver operating characteristic curve analysis was used to determine a discriminatory cutoff level for TAT complexes.

Results

TAT concentration was significantly higher in women who delivered preterm (median, 98.9 mcg/L) than in those who did not (median, 66.3 mcg/L; P < .001). This difference persisted when 55 spontaneous preterm deliveries (median, 87.6 mcg/L) and 34 indicated preterm deliveries (median, 117.7 mcg/L) were separately compared with controls (P = .04 and P < .001, respectively). Crude and adjusted odds ratio for preterm delivery in the upper 2 TAT quartiles relative to the uppermost quartile relative to the lowest quartile were 2.45 (95% confidence interval [CI], 1.36–4.72; P = .004) and 2.31 (95% CI, 1.18–4.65; P = .017), respectively. Despite these distinct differences, the area under the receiver operating characteristic curve was only 0.62 (95% CI, 0.56−0.69), indicating poor performance of TAT concentration as a risk discriminator.

Conclusion

Amniotic fluid levels of TAT complexes in the second trimester are elevated in women who subsequently deliver preterm, suggesting that thrombin generation may be involved in the various etiopathogenic mechanisms leading to preterm delivery.

Le texte complet de cet article est disponible en PDF.

Key words : amniotic fluid, preterm birth, thrombin-antithrombin complexes


Plan


 The authors report no conflict of interest.
 The racing flag logo above indicates that this article was rushed to press for the benefit of the scientific community.
 Reprints not available from authors.
 Cite this article as: Vidaeff AC, Mongan M, Ramin SM, et al. Is thrombin activation predictive of subsequent preterm delivery? Am J Obstet Gynecol 2013;208:306.e1-7.


© 2013  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 208 - N° 4

P. 306.e1-306.e7 - avril 2013 Retour au numéro
Article précédent Article précédent
  • Management strategy in pregnancies with elevated second-trimester maternal serum alpha-fetoprotein based on a second assay
  • Emmanuel Spaggiari, Marie Ruas, Sophie Dreux, Anne-Sylvie Valat, Isabelle Czerkiewicz, Fabien Guimiot, Thomas Schmitz, Anne-Lise Delezoide, Françoise Muller
| Article suivant Article suivant
  • Pioglitazone therapy in mouse offspring exposed to maternal obesity
  • Arshag Kalanderian, Nicola Abate, Igor Patrikeev, Jingna Wei, Kathleen Listiak Vincent, Massoud Motamedi, George Robert Saade, Egle Bytautiene

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.