Volumetric Left Ventricular Ejection Fraction is Superior to 2-Dimensional Echocardiography for Risk Stratification of Patients for Primary Prevention Implantable Cardioverter-Defibrillator Implantation - 02/04/13

Doi : 10.1016/j.amjcard.2012.12.051 
Hussein Rayatzadeh, MD a, Shalin J. Patel, MD a, Thomas H. Hauser, MD a, Long L. Ngo, PhD a, Jaime L. Shaw, BS a, Alex Tan, MD a, Alfred E. Buxton, MD a, Peter Zimetbaum, MD a, Mark E. Josephson, MD a, Evan Appelbaum, MD a, Warren J. Manning, MD a, b, Reza Nezafat, PhD a,
a Department of Medicine, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 
b Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, Massachusetts 

Corresponding author: Tel: (617) 667-1747; fax: (617) 975-5480.

Abstract

Current guidelines recommend an implantable cardioverter-defibrillator (ICD) according to the left ventricular ejection fraction (LVEF). However, they do not mandate volumetric LVEF assessment. We sought to determine whether volumetric LVEF measurement using cardiovascular magnetic resonance imaging (CMR-LVEF) is superior to conventional LVEF measurement using 2-dimensional transthoracic echocardiography (Echo-LVEF) for risk stratifying patients referred for primary prevention ICD. Patients who underwent primary prevention ICD implantation at our institution and had undergone preimplantation CMR-LVEF from November 2001 to February 2011 were identified. Volumetric CMR-LVEF was determined from cine short-axis data sets. CMR-LVEF and Echo-LVEF were extracted from the clinical reports. The end point was appropriate ICD discharge (shock and/or antitachycardia pacing). Of 48 patients, appropriate ICD discharge occurred in 9 (19%) within 29 ± 25 months (range 1 to 99, median 20). All patients met the Echo-LVEF criteria for ICD implantation; however 25% (95% confidence interval 13% to 37%) did not meet the CMR-LVEF criteria. None (0%) of these latter patients had received an appropriate ICD discharge. Using CMR-LVEF ≤30% as a threshold for ICD eligibility, 19 patients (40%) with a qualifying Echo-LVEF would not have been referred for ICD, and none (0%) received an ICD discharge.For primary prevention ICD implantation, volumetric CMR-LVEF might be superior to clinical Echo-LVEF for risk stratification and can identify a large minority of subjects in whom ICD implantation can be safely avoided. In conclusion, if confirmed by larger prospective series, volumetric methods such as CMR should be considered a superior “gatekeeper” for the identification of patients likely to benefit from primary prevention ICD implantation.

Le texte complet de cet article est disponible en PDF.

Plan


 This study was funded in part by grant R01EB008743-01 from the National Institutes of Health (Bethesda, Maryland) and grant 1 UL1 RR025758-01 from the National Center for Research Resources, National Institutes of Health (Bethesda, Maryland).
 The contents of our report are solely the responsibility of the authors and do not necessarily represent the official views of the National Institutes of Health or National Center for Research Resources (Bethesda, Maryland).
 See page 1179 for disclosure information.


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 111 - N° 8

P. 1175-1179 - avril 2013 Retour au numéro
Article précédent Article précédent
  • Relation of Statin Therapy to Psychological Functioning in Patients With an Implantable Cardioverter Defibrillator
  • Madelein T. Hoogwegt, Dominic A.M.J. Theuns, Nina Kupper, Luc Jordaens, Susanne S. Pedersen
| Article suivant Article suivant
  • Usefulness of Albuminuria as a Prognostic Indicator in Patients With Chronic Heart Failure Secondary to Ischemic or Idiopathic Dilated Cardiomyopathy
  • Takeshi Niizeki, Yasuchika Takeishi, Toshiki Sasaki, Kazuyoshi Kaneko, Shigeo Sugawara, Tetsu Watanabe, Isao Kubota

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.