Decremental Left Ventricular Deformation after Pulmonary Artery Band Training and Subsequent Repair in Ventriculoarterial Discordance - 21/06/13

Doi : 10.1016/j.echo.2013.03.017 
Heather Y. Sun, MD , Fariborz Behzadian, MD, Rajesh Punn, MD, Theresa A. Tacy, MD
Lucile Packard Children's Hospital, Stanford University, Palo Alto, California 

Reprint requests: Heather Y. Sun, MD, Lucile Packard Children's Hospital, Stanford University, Division of Pediatric Cardiology, 750 Welch Road, Suite 325, Palo Alto, CA 94304.

Abstract

Background

Patients with ventriculoarterial discordance, such as congenitally corrected and d-transposition of the great arteries, may undergo a morphologic left ventricular (LV) training strategy consisting of surgical pulmonary artery band (PAB) placement and subsequent anatomic repair to establish ventriculoarterial concordance. The purpose of this study was to characterize morphologic LV function and deformation longitudinally using speckle-tracking strain analysis in patients with ventriculoarterial discordance who underwent LV training.

Methods

Twenty-nine patients (12 with d-transposition of the great arteries and 17 with congenitally corrected transposition of the great arteries) who underwent LV training with PAB placement were evaluated retrospectively. LV ejection fraction and global and regional longitudinal strain and strain rate were measured before and 7 ± 5 days after PAB placement and subsequent anatomic repair.

Results

PAB placement caused reductions in the mean LV ejection fraction from 76.1 ± 10.2% to 66.7 ± 7.8% (P < .001), in mean global strain from −17.7 ± 9% to −13.3 ± 7.5% (P = .01), and in mean lateral wall strain from −23.3 ± 12.8% to −17.5 ± 10.3% (P = .01). After anatomic repair (a median of 21 months after PAB placement; range, 0.5–104 months), mean LV ejection fraction decreased further from 63.3 ± 8.6% to 52.4 ± 14.9% (P < .05). Mean global strain declined from −17.6% ± 4.4 to −12.6 ± 4% (P = .01), and mean lateral wall strain decreased from −18.2 ± 11.4% to −12.6 ± 5.3% (P = .04).

Conclusions

In patients with ventriculoarterial discordance undergoing PAB placement for LV training and anatomic repair, the morphologic left ventricle demonstrated decremental systolic function and global longitudinal deformation acutely. Frequent functional assessment is warranted to understand long-term myocardial mechanics in these patients.

Le texte complet de cet article est disponible en PDF.

Keywords : Pediatric cardiology, Myocardial strain, Transposition, Ventriculoarterial discordance, Pulmonary artery banding

Abbreviations : cc-TGA, d-TGA, LV, LVEF, PAB, RV, VVI


Plan


© 2013  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 7

P. 765-774 - juillet 2013 Retour au numéro
Article précédent Article précédent
  • The Assessment of Atrial Function in Single Ventricle Hearts from Birth to Fontan: A Speckle-Tracking Study by Using Strain and Strain Rate
  • Nee Scze Khoo, Jeffrey F. Smallhorn, Sachie Kaneko, Shelby Kutty, Luis Altamirano, Edythe B. Tham
| Article suivant Article suivant
  • Regional Difference of Microcirculation in Patients with Asymmetric Hypertrophic Cardiomyopathy: Transthoracic Doppler Coronary Flow Velocity Reserve Analysis
  • Milorad Tesic, Ana Djordjevic-Dikic, Branko Beleslin, Danijela Trifunovic, Vojislav Giga, Jelena Marinkovic, Olga Petrovic, Milan Petrovic, Jelena Stepanovic, Milan Dobric, Vladan Vukcevic, Goran Stankovic, Petar Seferovic, Miodrag Ostojic, Bosiljka Vujisic-Tesic

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.