Effectiveness of an Oxidized Cellulose Patch Hemostatic Agent in Thyroid Surgery: A Prospective, Randomized, Controlled Study - 20/07/13

Abstract |
Background |
This single-blinded, prospective, randomized controlled trial compared the efficacy and safety of an oxidized cellulose patch (Surgicel [Johnson and Johnson]) with conventional procedures for achieving hemostasis in thyroid surgery.
Study Design |
The study included 190 patients scheduled for thyroidectomy. Patients were randomized into 1 conventionally treated (ligatures and bipolar electrocautery) group (n = 92) and a second group, which additionally received Surgicel (n = 98).
Results |
The groups were demographically and clinically matched and had similar wound drainage volumes and mean duration of surgery. Postoperative bleeding rate was greater in the Surgicel group, yet the difference didn't reach statistical significance (p = 0.054). There were no significant group differences in postoperative wound infection, seroma, hypocalcemia, or recurrent laryngeal nerve palsy. Time to drain removal and length of hospital stay were significantly shorter in the conventional group (p < 0.001).
Conclusions |
Routine use of an oxidized cellulose hemostatic agent has no advantage over conventional hemostasis and is potentially harmful in thyroid surgery.
Le texte complet de cet article est disponible en PDF.Plan
| CME questions for this article available at jacscme.facs.org |
|
| Disclosure Information: Authors have nothing to disclose. Timothy J Eberlein, Editor-in-Chief, has nothing to disclose. |
Vol 217 - N° 2
P. 221-225 - août 2013 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?