S'abonner

Experts and Beginners Benefit from Three-Dimensional Echocardiography: A Multicenter Study on the Assessment of Mitral Valve Prolapse - 24/07/13

Doi : 10.1016/j.echo.2013.04.015 
Maximilian Dominik Hien, MD a, b, d, Manuel Großgasteiger, Cand Med a, d, Helmut Rauch, MD d, Alexander Weymann, MD c, Raffi Bekeredjian, Prof, MD e, Christian Rosendal, MD f,
a Research Training Group 1126, German Research Foundation, Heidelberg, Germany 
b Department of Pediatrics, University of Heidelberg, Heidelberg, Germany 
c Department of Cardiac Surgery, University of Heidelberg, Heidelberg, Germany 
d Department of Anaesthesiology, University of Heidelberg, Heidelberg, Germany 
e Department of Internal Medicine, University of Heidelberg, Heidelberg, Germany 
f Hirslanden Clinics Berne, Klinik Beau-Site, Bern, Switzerland 

Reprint requests: Christian Rosendal, MD, Hirslanden Clinics Berne, Klinik Beau-Site, Schänzlihalde 11, 3000 Bern 25, Switzerland.

Abstract

Background

Three-dimensional (3D) transesophageal echocardiography (TEE) has been claimed to provide more information than two-dimensional (2D) TEE in the localization of mitral valve prolapse (MVP). However, most studies have been performed by experts in echocardiography, without accounting for differences in training or expertise. This multicenter study was designed to assess the differences between experts and inexperienced echocardiographers in localizing MVP and ruptured chordae tendineae using 2D and real-time 3D TEE.

Methods

Thirty-six observers from 10 institutions in Germany and Switzerland interpreted 2D and 3D transesophageal echocardiographic images from six patients selected to represent a large spectrum of MVP diversity. Surgical findings served as a reference. Individual performance in the prediction of pathology was scored. Differences between 15 experts and 21 beginners in TEE were assessed, and the benefits conferred by 3D TEE were compared.

Results

Both study groups scored significantly higher when interpreting 3D transesophageal echocardiographic images (P ≤ .001). The experts were superior in 2D MVP localization (14.8%; P ≤ .001), a difference that diminished with 3D TEE (1.4%; P = .41). The benefit of access to 3D information for MVP localization was greater for inexperienced echocardiographers compared with experts (P < .001).

Conclusions

The reported diagnostic advantage of 3D TEE over 2D TEE in MVP assessment for expert echocardiographers can be transferred to inexperienced echocardiographers. Inexperienced echocardiographers benefit from the technology to a greater extent than their expert colleagues.

Le texte complet de cet article est disponible en PDF.

Keywords : Experience, Training, Education, Mitral valve prolapse assessment, Three-dimensional transesophageal echocardiography

Abbreviations : ChR, MV, MVP, TEE, 3D, 2D


Plan


 M.D.H. and M.G. are supported by Research Training Group 1126, which is funded by the German Research Foundation.


© 2013  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 8

P. 828-834 - août 2013 Retour au numéro
Article précédent Article précédent
  • Can We Talk? Reflections on Effective Communication between Imager and Interventionalist in Congenital Heart Disease
  • Shelby Kutty, Jeffrey W. Delaney, Larry A. Latson, David A. Danford
| Article suivant Article suivant
  • Three-Dimensional Transesophageal Echocardiographic Evaluation of Coronary Involvement in Patients with Acute Type A Aortic Dissection
  • Shunsuke Sasaki, Hiroyuki Watanabe, Kentaro Shibayama, Keitaro Mahara, Minoru Tabata, Toshihiro Fukui, Tetsuya Tobaru, Shuichiro Takanashi, Tetsuya Sumiyoshi, Hitonobu Tomoike

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.