S'abonner

Application of the Multicenter Automatic Defibrillator Implantation Trial II Risk Score in a Nontrial Setting - 01/08/13

Doi : 10.1016/j.amjcard.2013.04.019 
Niyada Naksuk, MD a, b, , Mehmet Akkaya, MD a, b, Selcuk Adabag, MD, MS a, b, c
a Division of Cardiology, Veterans Administration Medical Center, Minneapolis, Minnesota 
b Department of Medicine, University of Minnesota, Minneapolis, Minnesota 
c Division of Epidemiology and Community Health, School of Public health, University of Minnesota, Minneapolis, Minnesota 

Corresponding author: Tel: (612) 206-0633; fax: (612) 727-5668.

Abstract

A post hoc analysis of the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II showed that patients with high mortality risk score did not benefit from implantable cardioverter-defibrillator (ICD) therapy. We sought to determine whether MADIT II risk score can identify patients with greater mortality in a nontrial “real-world” setting. We included 382 consecutive patients who received ICD for primary prevention of sudden cardiac death at the Minneapolis Veterans Affairs Medical Center from 2006 to 2010. MADIT II score was calculated by assigning 1 point each for age >70 years, New York Heart Association class >II, atrial fibrillation, QRS >0.12 seconds, and blood urea nitrogen level >26 mg/dl. Scores 0, 1 to 2, and ≥3 were classified as low, intermediate, and high risk, respectively. Of the 382 patients, 14% were low risk, 54% intermediate risk, and 32% high risk. After 3.0 ± 1.6 years of follow-up, incidence of appropriate ICD shocks was similar (p = 0.21) across MADIT II risk score categories. However, mortality rate was 21, 54, and 134 per 1,000 patient-year follow-up in low, intermediate, and high-risk patients, respectively, p <0.0001. Compared with low-risk patients, mortality was 6.4× greater in high-risk patients (hazard ratio 6.36, 95% confidence interval 1.9 to 20.5; p = 0.002). The c-index for the MADIT II score for predicting death was 0.69 (95% confidence interval 0.63 to 0.75). In conclusion, MADIT II risk score successfully identified patients with greater mortality in a nontrial-based, primary-prevention ICD cohort.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 532 for disclosure information.


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 4

P. 530-532 - août 2013 Retour au numéro
Article précédent Article précédent
  • Effect on Cardiac Function of Cardiac Resynchronization Therapy in Patients With Right Bundle Branch Block (from the Multicenter Automatic Defibrillator Implantation Trial With Cardiac Resynchronization Therapy [MADIT-CRT] Trial)
  • Christine Tompkins, Valentina Kutyifa, Scott McNitt, Bronislava Polonsky, Helmut U. Klein, Arthur J. Moss, Wojciech Zareba
| Article suivant Article suivant
  • Relation of Short-Term Heart Rate Variability to Incident Heart Failure (from the Multi-Ethnic Study of Atherosclerosis)
  • Sidharth A. Shah, Thomas Kambur, Cheeling Chan, David M. Herrington, Kiang Liu, Sanjiv J. Shah

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.