Accuracy of Three-Dimensional Versus Two-Dimensional Echocardiography for Quantification of Aortic Regurgitation and Validation by Three-Dimensional Three-Directional Velocity-Encoded Magnetic Resonance Imaging - 01/08/13

Doi : 10.1016/j.amjcard.2013.04.025 
See Hooi Ewe, MBBS a, b, Victoria Delgado, MD, PhD a, , Rob van der Geest, MSc, PhD c, Jos J.M. Westenberg, PhD c, Marlieke L.A. Haeck, MD a, Tomasz G. Witkowski, MD a, Dominique Auger, MD a, Nina Ajmone Marsan, MD a, Eduard R. Holman, MD, PhD a, Albert de Roos, MD, PhD c, Martin J. Schalij, MD, PhD a, Jeroen J. Bax, MD, PhD a, Allard Sieders, MD d, Hans-Marc J. Siebelink, MD, PhD a
a Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands 
b Department of Cardiology, National Heart Centre, Singapore 
c Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands 
d Department of Cardiology, Rijnland Ziekenhuis, Leiderdorp, The Netherlands 

Corresponding author: Tel: +31715262020; fax: +31715266809.

Abstract

Quantitative assessment of aortic regurgitation (AR) remains challenging. The present study evaluated the accuracy of 2-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (TTE) for AR quantification, using 3D 3-directional velocity-encoded magnetic resonance imaging (VE-MRI) as the reference method. Thirty-two AR patients were included. With color Doppler TTE, 2D effective regurgitant orifice area (EROA) was calculated using the proximal isovelocity surface area method. From the 3D TTE multiplanar reformation data, 3D-EROA was calculated by planimetry of the vena contracta. Regurgitant volumes (RVol) were obtained by multiplying the 2D-EROA and 3D-EROA by the velocity-time integral of AR jet and compared with that obtained using VE-MRI. For the entire population, 3D TTE RVol demonstrated a strong correlation and good agreement with VE-MRI RVol (r = 0.94 and −13.6 to 15.6 ml/beat, respectively), whereas 2D TTE RVol showed a modest correlation and large limits of agreement with VE-MRI (r = 0.70 and −22.2 to 32.8 ml/beat, respectively). Eccentric jets were noted in 16 patients (50%). In these patients, 3D TTE demonstrated an excellent correlation (r = 0.95) with VE-MRI, a small bias (0.1 ml/beat) and narrow limits of agreement (−18.7 to 18.8 ml/beat). Finally, the kappa agreement between 3D TTE and VE-MRI for grading of AR severity was good (k = 0.96), whereas the kappa agreement between 2D TTE and VE-MRI was suboptimal (k = 0.53). In conclusion, AR RVol quantification using 3D TTE is accurate, and its advantage over 2D TTE is particularly evident in patients with eccentric jets.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 565 for disclosure information.


© 2013  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 112 - N° 4

P. 560-566 - août 2013 Retour au numéro
Article précédent Article précédent
  • Comparison of Incidence and Predictors of Left Bundle Branch Block After Transcatheter Aortic Valve Implantation Using the CoreValve Versus the Edwards Valve
  • Irene Franzoni, Azeem Latib, Francesco Maisano, Charis Costopoulos, Luca Testa, Filippo Figini, Francesco Giannini, Sandeep Basavarajaiah, Marco Mussardo, Massimo Slavich, Maurizio Taramasso, Micaela Cioni, Matteo Longoni, Santo Ferrarello, Andrea Radinovic, Simone Sala, Silvia Ajello, Alessandro Sticchi, Manuela Giglio, Eustachio Agricola, Alaide Chieffo, Matteo Montorfano, Ottavio Alfieri, Antonio Colombo
| Article suivant Article suivant
  • Predictors of Left Ventricular Remodeling After Surgical Repair or Replacement for Pure Severe Mitral Regurgitation Caused by Leaflet Prolapse
  • Mario Sénéchal, Jimmy MacHaalany, Olivier F. Bertrand, Kim O'Connor, Julie Parenteau, Isaïe-Nicolas Dubois-Sénéchal, Olivier Costerousse, Michelle Dubois, Pierre Voisine

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.