S'abonner

Laparoscopic Needle-Retrieval Device for Improving Quality of Care in Minimally Invasive Surgery - 20/08/13

Doi : 10.1016/j.jamcollsurg.2013.02.035 
Alexander C. Small, BA a, Daniel M. Gainsburg, MD b, Miguel A. Mercado, MD c, Richard E. Link, MD, PhD c, Sean P. Hedican, MD d, Michael A. Palese, MD a,
a Department of Urology, Mount Sinai School of Medicine, New York, NY 
b Department of Anesthesiology, Mount Sinai School of Medicine, New York, NY 
c Scott Department of Urology, Baylor College of Medicine, Houston, TX 
d Department of Urology, University of Wisconsin, Madison, WI 

Correspondence address: Michael A Palese, MD, Department of Urology, Mount Sinai School of Medicine, 5 East 98th St, 4th Fl, New York, NY 10029.

Abstract

Background

Loss of a needle during laparoscopic surgery is a rare but potentially serious adverse event that can cause prolonged operative time and patient harm. Standard recovery techniques currently include instrument count, standard visual search, and plain abdominal x-rays. We developed a laparoscopic instrument to speed the retrieval of lost needles in the abdomen and pelvis.

Study Design

We performed in vivo testing of a novel articulating laparoscopic magnet in a porcine model. Three experienced surgeons and 3 inexperienced surgeons conducted 116 needle-retrieval trials with the device and 58 trials with a standard visual approach. Surgeons were blind to the locations of randomly placed surgical needles within the abdominal cavity. Time to recovery was measured and capped at 15 minutes. Analysis was performed using univariate and multivariable methods.

Results

The magnetic device was able to retrieve needles significantly faster than the standard approach (2.9 ± 4.0 minutes vs 8.0 ± 6.0 minutes; p < 0.0001). On multivariable analysis, faster recovery time remained independently significant when controlling for surgeon experience, needle size (small, medium, or large), and needle location (by quadrant) (p < 0.0001). There were 2 (2%) injuries to abdominal organs during the device trials and 4 (7%) injuries during the standard trials (p = 0.182).

Conclusions

Recovery of lost surgical needles during porcine laparoscopic surgery is safe and feasible with a simple articulating magnetic device. Our initial in vivo experience suggests that recovery is markedly faster using the magnetic device than the standard approach, even in the hands of experienced laparoscopic surgeons. This device will be particularly useful as minimally invasive robotic and single-site surgical techniques are adopted and, in the future, it should be integrated into the standard protocol for locating lost needles during surgery.

Le texte complet de cet article est disponible en PDF.

Plan


 Disclosure Information: Drs Gainsburg and Palese have a patent pending on a “Magnetic Based Device for Retrieving a Misplaced Article.” All other authors have nothing to disclose.
 This project was supported by a Technology Development Funding Grant from The Mount Sinai Medical Center.


© 2013  American College of Surgeons. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 217 - N° 3

P. 400-405 - septembre 2013 Retour au numéro
Article précédent Article précédent
  • Adherence of Randomized Trials Within Children's Surgical Specialties Published During 2000 to 2009 to Standard Reporting Guidelines
  • Martin L. Blakely, Lillian S. Kao, Kuojen Tsao, Eunice Y. Huang, Anthony Tsai, Stacy Tanaka, Shiraz Younas, Zengqi Lu, Kevin P. Lally, Pediatric Surgery Research Collaborative
| Article suivant Article suivant
  • Retrocaval Renal Artery Bifurcation Is Not a Contraindication to Laparoscopic Right Donor Nephrectomy
  • Jason A. Gandelman, Peter S. Yoo, Sanjay Kulkarni

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.