Bad design, bad practices, bad bugs: frustrations in controlling an outbreak of Elizabethkingia meningoseptica in intensive care units - 17/09/13

Doi : 10.1016/j.jhin.2013.05.012 
M.N.D. Balm a, b, S. Salmon a, R. Jureen b, C. Teo a, R. Mahdi a, T. Seetoh c, J.T.W. Teo b, R.T.P. Lin a, b, D.A. Fisher a, d,
a Infection Control Team, National University Hospital, Singapore 
b Microbiology, Department of Laboratory Medicine, National University Hospital, Singapore 
c Ministry of Health Holdings, Harbour Front Centre, Singapore 
d Division of Infectious Diseases, University Medicine Cluster, National University Health System, Singapore 

Corresponding author. Address: Department of Medicine, National University Health System, 1E Kent Ridge Road, NUHS Tower Block, Level 10, Singapore 119228. Tel.: +65 67724373; fax: +65 677941127.

Summary

Background

Elizabethkingia meningoseptica is a nosocomial-adapted Gram-negative bacillus intrinsically resistant to antibiotics commonly used in the intensive care setting. An outbreak investigation commenced when five patients developed E. meningoseptica infection in two intensive care units (ICUs).

Methods

Analysis of laboratory data, case reviews, ICU workflows and extensive environmental sampling were undertaken. Molecular typing was performed using repetitive element palindromic polymerase chain reaction. Follow-up studies after interventions included environmental monitoring and a survey of staff compliance with interventions.

Findings

Laboratory data revealed increasing incidence of E. meningoseptica colonization or infection in ICU patients compared with preceding years. E. meningoseptica was cultured from 44% (35/79) of taps, but not from other sources. Hand hygiene sinks were used for disposal of patient secretions and rinsing re-usable patient care items. Sinks misused in this way were contaminated more often than sinks that were not misused (odds ratio 4.38, 95% confidence interval 1.68–11.39; P = 0.004). Molecular typing revealed that patient isolates had identical patterns to several isolates from hand hygiene taps. An urgent education programme was instituted to change these practices. Taps were cleaned systematically and aerators were changed. A temporary reduction in case numbers was achieved. Recolonization of taps was demonstrated on follow-up environmental screening, and cases recurred after two months. A survey revealed that 77.3% (163/213) of nursing staff still misused sinks due to time constraints or other problems adhering to the interventions.

Conclusion

Introduction of non-sanctioned practices due to suboptimal unit design may have unintentional consequences for ICU patients. Room design and staff workflows must be optimized for patient safety as lapses in procedure can inadvertently put patients at risk.

Le texte complet de cet article est disponible en PDF.

Keywords : Intensive care outbreak, Gram-negative non-fermenter, Elizabethkingia meningoseptica, Tap contamination


Plan


© 2013  The Healthcare Infection Society. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 85 - N° 2

P. 134-140 - octobre 2013 Retour au numéro
Article précédent Article précédent
  • Laying-up of sterile instruments in the operating theatre: equal or superior protection by using a horizontal unidirectional air flow system
  • A.A.L. Traversari, C.A. Goedhart, E. Dusseldorp, A. Bode, F. Keuning, M.S.J. Pelk, M.C. Vos
| Article suivant Article suivant
  • Sustained meticillin-resistant Staphylococcus aureus control in a hyper-endemic tertiary acute care hospital with infrastructure challenges in Singapore
  • D. Fisher, P.A. Tambyah, R.T.P. Lin, R. Jureen, A.R. Cook, A. Lim, B. Ong, M. Balm, T.M. Ng, L.Y. Hsu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.