S'abonner

Three-Dimensional Color Doppler Echocardiographic Quantification of Tricuspid Regurgitation Orifice Area: Comparison with Conventional Two-Dimensional Measures - 21/09/13

Doi : 10.1016/j.echo.2013.07.020 
Tien-En Chen, MD a, b, c, Susan H. Kwon, MD a, Maurice Enriquez-Sarano, MD a, Benjamin F. Wong, MD a, Sunil V. Mankad, MD a,
a Division of Cardiovascular Disease, Mayo Clinic, Rochester, Minnesota 
b Division of Cardiology, Department of Internal Medicine, China Medical University Hospital, Taichung, Taiwan 
c Medical College, China Medical University, Taichung, Taiwan 

Reprint requests: Sunil V. Mankad, MD, Division of Cardiovascular Disease, Mayo Clinic, 200 First Street SW, Rochester, MN 55905.

Abstract

Background

Three-dimensional (3D) color Doppler echocardiography (CDE) provides directly measured vena contracta area (VCA). However, a large comprehensive 3D color Doppler echocardiographic study with sufficiently severe tricuspid regurgitation (TR) to verify its value in determining TR severity in comparison with conventional quantitative and semiquantitative two-dimensional (2D) parameters has not been previously conducted. The aim of this study was to examine the utility and feasibility of directly measured VCA by 3D transthoracic CDE, its correlation with 2D echocardiographic measurements of TR, and its ability to determine severe TR.

Methods

Ninety-two patients with mild or greater TR prospectively underwent 2D and 3D transthoracic echocardiography. Two-dimensional evaluation of TR severity included the ratio of jet area to right atrial area, vena contracta width, and quantification of effective regurgitant orifice area using the flow convergence method. Full-volume breath-hold 3D color data sets of TR were obtained using a real-time 3D echocardiography system. VCA was directly measured by 3D-guided direct planimetry of the color jet. Subgroup analysis included the presence of a pacemaker, eccentricity of the TR jet, ellipticity of the orifice shape, underlying TR mechanism, and baseline rhythm.

Results

Three-dimensional VCA correlated well with effective regurgitant orifice area (r = 0.62, P < .0001), moderately with vena contracta width (r = 0.42, P < .0001), and weakly with jet area/right atrial area ratio. Subgroup analysis comparing 3D VCA with 2D effective regurgitant orifice area demonstrated excellent correlation for organic TR (r = 0.86, P < .0001), regular rhythm (r = 0.78, P < .0001), and circular orifice (r = 0.72, P < .0001) but poor correlation in atrial fibrillation rhythm (r = 0.23, P = .0033). Receiver operating characteristic curve analysis for 3D VCA demonstrated good accuracy for severe TR determination.

Conclusions

Three-dimensional VCA measurement is feasible and obtainable in the majority of patients with mild or greater TR. Three-dimensional VCA measurement is also feasible in patients with atrial fibrillation but performed poorly even with <20% cycle length variation. Three-dimensional VCA has good cutoff accuracy in determining severe TR. This simple, straightforward 3D color Doppler measurement shows promise as an alternative for the quantification of TR.

Le texte complet de cet article est disponible en PDF.

Keywords : Three-dimensional color Doppler echocardiography, Tricuspid regurgitation, Vena contracta area, Effective regurgitant orifice area, Valvular heart disease

Abbreviations : AF, CDE, EROA, JA, MPR, MR, PISA, RAA, ROC, RV, 3D, TR, TV, 2D, VCA, VCW


Plan


© 2013  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 26 - N° 10

P. 1143-1152 - octobre 2013 Retour au numéro
Article précédent Article précédent
  • Calcification of the Mitral Valve and Annulus: Systematic Evaluation of Effects on Valve Anatomy and Function
  • Rajesh Movva, Kinnari Murthy, Abel Romero-Corral, Harish Raj Seetha Rammohan, Peter Fumo, Gregg S. Pressman
| Article suivant Article suivant
  • Left Ventricular Systolic Function in Ischemic Mitral Regurgitation: Time to Look beyond Ejection Fraction
  • Julien Magne, Philippe Pibarot

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.