S'abonner

Evaluation of microfocused ultrasound with visualization for lifting, tightening, and wrinkle reduction of the décolletage - 14/11/13

Doi : 10.1016/j.jaad.2013.06.045 
Sabrina G. Fabi, MD a, b, , Ane Massaki, MD a, Sasima Eimpunth, MD b, Janice Pogoda, PhD c, Mitchel P. Goldman, MD a, b
a Goldman, Butterwick, Fitzpatrick, Groff, and Fabi, Cosmetic Laser Dermatology, San Diego, California 
b University of California, San Diego, California 
c Department of Preventive Medicine, Keck School of Medicine, University of Southern California, Los Angeles, California 

Correspondence to: Sabrina G. Fabi, MD, Goldman, Butterwick, Fitzpatrick, Groff, and Fabi, Cosmetic Laser Dermatology, 9339 Genesee Ave, Suite 300, San Diego, CA 92121.

Abstract

Background

Laxity and rhytides are manifestations of photodamage on the chest.

Objective

We sought to evaluate efficacy and safety of microfocused ultrasound with visualization treatment of décolletage laxity and rhytides.

Methods

In all, 24 subjects with moderate to severe rhytides, as measured by a validated 5-point photonumeric scale (Fabi/Bolton Chest Wrinkle Scale), received microfocused ultrasound with visualization treatment. Efficacy was measured at 90 and 180 days by the Fabi/Bolton Chest Wrinkle Scale, mid-clavicular to nipple distance, masked assessment, Physician and Subject Global Aesthetic Improvement Scales, and patient satisfaction. Adverse events were recorded.

Results

Rhytides improved over time (P < .0001), with 46% and 62% of subjects showing a 1- to 2-point improvement at days 90 and 180, respectively. Mean (SD) mid-clavicular to nipple distance decreased (P < .0001), from 20.9 (1.57) cm to 19.8 (1.50) cm and 19.5 (1.59) cm, at days 90 and 180, respectively. At day 90, 100% were improved by Subject Global Aesthetic Improvement Scale score (P < .0001) and 96% were improved by Physician Global Aesthetic Improvement Scale score (P < .0001), with similar findings at day 180. All subjects were satisfied or very satisfied at day 90, with similar results at day 180. Improvement by masked assessment at day 90 was 71%.

Limitations

Single-center study, small sample size, and only Fitzpatrick skin types I and II enrolled were limitations.

Conclusion

There was appreciable efficacy and patient satisfaction after a single microfocused ultrasound with visualization treatment in wrinkle reduction and lifting of the décolletage.

Le texte complet de cet article est disponible en PDF.

Key words : chest, décolletage, microfocused ultrasound with visualization, photoaging, tightening, wrinkles

Abbreviations used : FBCWS, MFU-V, PGAIS, PIH, SGAIS


Plan


 Supported by a research grant from Ulthera Inc.
 Disclosure: Dr Fabi is a consultant for Ulthera Inc. Drs Massaki, Eimpunth, Pogoda, and Goldman have no conflicts of interest to declare.
 Reprints not available from the authors.


© 2013  American Academy of Dermatology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 69 - N° 6

P. 965-971 - décembre 2013 Retour au numéro
Article précédent Article précédent
  • Important Notice Regarding JAAD Grand Rounds
| Article suivant Article suivant
  • Current status of surgery in dermatology
  • C. William Hanke, Ronald L. Moy, Randall K. Roenigk, Henry H. Roenigk, James M. Spencer, Emily P. Tierney, Cynthia L. Bartus, Robert M. Bernstein, Marc D. Brown, Mariano Busso, Alastair Carruthers, Jean Carruthers, Omar A. Ibrahimi, Arielle N.B. Kauvar, Kathryn M. Kent, Nils Krueger, Marina Landau, Aimee L. Leonard, Stephen H. Mandy, Thomas E. Rohrer, Neil S. Sadick, Luitgard G. Wiest

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.