S'abonner

A Simple Effective Method for Generation of a Permanent Record of the Critical View of Safety during Laparoscopic Cholecystectomy by Intraoperative “Doublet” Photography - 15/01/14

Doi : 10.1016/j.jamcollsurg.2013.11.003 
Dominic E. Sanford, MD, Steven M. Strasberg, MD, FACS
 Section of Hepato-Pancreato-Biliary Surgery, Department of Surgery, Washington University in St Louis and Barnes-Jewish Hospital, St Louis, MO 

Correspondence address: Steven M Strasberg, MD, FACS, Section of Hepato-Pancreato-Biliary Surgery, Department of Surgery, Washington University in St Louis, 4990 Children’s Pl, Suite 1160, Box 8109, St Louis, MO 63110.

Abstract

Background

The Critical View of Safety (CVS) is an established method for identifying the cystic duct during laparoscopic cholecystectomy. Its goal is to prevent misidentification of the bile ducts and avoid biliary injury. However, a visual record of CVS is not usually made. Intraoperative photography has the potential to record CVS and increase the safety of laparoscopic cholecystectomy. The objective of this study was to develop a simple and effective technique for recording CVS during laparoscopic cholecystectomy.

Study Design

Techniques for photographing and rating photographs of CVS were developed. Surgeons were trained in methods of photographing both anterior and posterior views of CVS during laparoscopic cholecystectomy. Independent observers scored these views individually and together. The term doublet view was used when both anterior and posterior views of CVS were used for rating. Three criteria for CVS were used for scoring photographs. A total score of ≥5 of 6 points was considered satisfactory, and a total score <5 of 6 points was considered unsatisfactory.

Results

Photographs of 28 patients were obtained. Critical View of Safety photographs were satisfactory in either anterior or posterior single images in 43 of 56 (76.8%) instances, and doublet photographs were satisfactory in 27 of 28 (96.4%) instances (p = 0.02). Body mass index >40 predicted a higher likelihood of unsatisfactory individual CVS photos (p = 0.02); however, there was no correlation between patient or pathologic factors and the scores of doublet views.

Conclusions

With training and adherence to straightforward photographic techniques, intraoperative doublet photography can record CVS accurately. This method is performed easily, and could be used for recording of CVS in the medical record.

Le texte complet de cet article est disponible en PDF.

Plan


 Disclosure Information: Nothing to disclose.


© 2014  American College of Surgeons. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 218 - N° 2

P. 170-178 - février 2014 Retour au numéro
Article précédent Article précédent
  • Assessment of Tumor Growth in Pancreatic Neuroendocrine Tumors in von Hippel Lindau Syndrome
  • Allison B. Weisbrod, Mio Kitano, Francine Thomas, David Williams, Neelam Gulati, Krisana Gesuwan, Yixun Liu, David Venzon, Ismail Turkbey, Peter Choyke, Jack Yao, Steven K. Libutti, Naris Nilubol, William M. Linehan, Electron Kebebew
| Article suivant Article suivant
  • Evaluation of Resistance as a Measure of Successful Tumor Ablation During Irreversible Electroporation of the Pancreas
  • Erik M. Dunki-Jacobs, Prejesh Philips, Robert CG. Martin

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.