S'abonner

Long Term Follow-Up After Aortic Valve Replacement (Ross Procedure): Echocardiographic Determinants of Ventricular Recovery - 24/02/14

Doi : 10.1016/j.hlc.2013.07.008 
William M. Wilson a, , Leeanne E. Grigg a, Alexandra Gorelik b, Peter Skillington c
a Department of Cardiology, Royal Melbourne Hospital, Parkville 3052, Australia 
b Melbourne EpiCentre, Royal Melbourne Hospital, Parkville 3052, Australia 
c Department of Cardiothoracic Surgery, Royal Melbourne Hospital, Parkville 3052, Australia 

Corresponding author. Tel.: +1 6479977745; fax: +61 393423130.

Résumé

Aims and Methods

This prospective cohort study aimed to assess LV recovery post aortic valve replacement, stratified according to pre-operative valve lesion (aortic stenosis (AS), mixed disease (AS/AR) or aortic regurgitation (AR)), as well as define predictors of persistent LV dilatation post operation. We prospectively followed all patients post Ross procedure performed between 1992 and 2009 by a single surgeon. Echocardiography was performed pre-operatively, at approximately one year post operation then second yearly thereafter.

Results

265 patients were followed for a mean of 6.4 years (range 1–14 years, total 1702 patient-years). Seventy percent were male and mean age was 38.8±12.6 years. The indication for surgery was AS in 44.5% (118), AS/AR in 23.4% (62), and AR in 32.1% (85). Overall mortality was 1.8% and 80% of deaths were non-cardiac. Morbidity was low and the need for pacing was less than 1%. Ninety-nine percent of patients were NYHA class 1 at one year follow up. The indexed LV end diastolic diameter (LVEDDi) decreased significantly post-operation in the AR (3.34±0.39–2.66±0.32cm/m2, p<0.001) and mixed (2.85±0.38–2.65±0.30cm/m2, p=0.01) groups, whilst the indexed systolic LV dimension decreased significantly post-operation in the AR group (2.26±0.34–1.87±0.27, p<0.001). At five years post operation, independent predictors for a larger LVEDDi were female gender, a pre-operative LVEDDi >3.0cm/m2 and the presence of mild aortic regurgitation at one year post-operation. Pre-operative valve lesion was not a predictor. The only independent predictor of a lesser reduction of LVEDDi at five year follow-up was mild post-operative AR, whilst predictors of a lesser reduction in indexed left ventricular end systolic diameter (LVESDi) at five year follow-up included mild post-operative AR and a larger pre-operative LVEDDi. LV wall thickness decreased significantly the AS and AS/AR groups within one year post operation, whilst the neo-aortic root size remained stable throughout follow-up.

Conclusions

Recovery of LV size post Ross procedure is influenced predominantly by the pre-operative LV size, in particular the indexed LV end diastolic diameter. The pre-operative valve lesion was not predictive of larger ventricular dimensions post AVR, but independent predictors of a larger ventricular dimensions post operation included female gender, enlarged pre-operative LVEDDi and the presence of mild AR in the first post operative year. Those with mild post-operative AR did not have progressive LV enlargement, thus the clinical significance of this finding remains unclear.

Le texte complet de cet article est disponible en PDF.

Keywords : Aortic valve replacement, Ross procedure, Left ventricular size


Plan


Crown Copyright © 2013  Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 2

P. 132-143 - février 2014 Retour au numéro
Article précédent Article précédent
  • Transcatheter Closure of Secundum Atrial Septal Defects: Results in Patients with Large and Extreme Defects
  • Giovanni Romanelli, Richard W. Harper, Philip M. Mottram
| Article suivant Article suivant
  • Effect of Haemodynamic Changes on Epithelium-related Intestinal Injury in Off-pump Coronary Surgery
  • Terézia B. Andrási, Florina Mertens, Brigitta Barabás, Anna Blázovics

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.