S'abonner

Standard forward-viewing colonoscopy versus full-spectrum endoscopy: an international, multicentre, randomised, tandem colonoscopy trial - 04/03/14

Doi : 10.1016/S1470-2045(14)70020-8 
Ian M Gralnek, ProfMD a, b, c, , , Peter D Siersema, MD d, , Zamir Halpern, MD e, Ori Segol, MD f, Alaa Melhem, MD e, Alain Suissa, MD a, c, Erwin Santo, MD e, Alan Sloyer, MD g, Jay Fenster, MD h, Leon M G Moons, MD d, Vincent K Dik, MD d, Ralph B D’Agostino, PhD i, Douglas K Rex, MD j
a Department of Gastroenterology, Rambam Health Care Campus, Haifa, Israel 
b Rappaport Faculty of Medicine, Technion—Israel Institute of Technology, Haifa, Israel 
c Gastrointestinal Endoscopy Unit, Elisha Hospital, Haifa, Israel 
d Department of Gastroenterology and Hepatology, University Medical Centre Utrecht, Netherlands 
e Department of Gastroenterology, Tel Aviv Sourasky Medical Centre and Tel Aviv University School of Medicine, Tel Aviv, Israel 
f Lady Davis Carmel Medical Centre, Haifa, Israel 
g North Shore Gastroenterology Associates, Great Neck, NY, USA 
h South Shore Gastroenterology, Cedarhurst, NY, USA 
i Wake Forest University School of Medicine, Winston-Salem, NC, USA 
j Indiana University Hospital, Indianapolis, IN, USA 

* Correspondence to: Prof Ian M Gralnek, Gastrointestinal Outcomes Unit, Department of Gastroenterology, Rambam Health Care Campus, Haifa 31096, Israel

Summary

Background

Although colonoscopy is the accepted standard for detection of colorectal adenomas and cancers, many adenomas and some cancers are missed. To avoid interval colorectal cancer, the adenoma miss rate of colonoscopy needs to be reduced by improvement of colonoscopy technique and imaging capability. We aimed to compare the adenoma miss rates of full-spectrum endoscopy colonoscopy with those of standard forward-viewing colonoscopy.

Methods

We did an international, multicentre, randomised trial at three sites in Israel, one site in the Netherlands, and two sites in the USA between Feb 1, 2012, and March 31, 2013. Patients aged 18–70 years referred for colorectal cancer screening, polyp surveillance, or diagnostic assessment underwent same-day, back-to-back tandem colonoscopy with standard forward-viewing colonoscope and the full-spectrum endoscopy colonoscope. The patients were randomly assigned (1:1), via computer-generated randomisation with block size of 20, to which procedure was done first. The endoscopist was masked to group allocation until immediately before the start of colonoscopy examinations; patients were not masked. The primary endpoint was adenoma miss rates. We did per-protocol analyses. This trial is registered with ClinicalTrials.gov, number NCT01549535.

Findings

197 participants were enrolled. 185 participants were included in the per-protocol analyses: 88 (48%) were randomly assigned to receive standard forward-viewing colonoscopy first, and 97 (52%) to receive full-spectrum endoscopy colonoscopy first. By per-lesion analysis, the adenoma miss rate was significantly lower in patients in the full-spectrum endoscopy group than in those in the standard forward-viewing procedure group: five (7%) of 67 vs 20 (41%) of 49 adenomas were missed (p<0·0001). Standard forward-viewing colonoscopy missed 20 adenomas in 15 patients; of those, three (15%) were advanced adenomas. Full-spectrum endoscopy missed five adenomas in five patients in whom an adenoma had already been detected with first-pass standard forward-viewing colonoscopy; none of these missed adenomas were advanced. One patient was admitted to hospital for colitis detected at colonoscopy, whereas five minor adverse events were reported including vomiting, diarrhoea, cystitis, gastroenteritis, and bleeding.

Interpretation

Full-spectrum endoscopy represents a technology advancement for colonoscopy and could improve the efficacy of colorectal cancer screening and surveillance.

Funding

EndoChoice.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Elsevier Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 15 - N° 3

P. 353-360 - mars 2014 Retour au numéro
Article précédent Article précédent
  • Pharmacokinetics and safety of subcutaneous rituximab in follicular lymphoma (SABRINA): stage 1 analysis of a randomised phase 3 study
  • Andrew Davies, Francesco Merli, Biljana Mihaljevic, Noppadol Siritanaratkul, Phillippe Solal-Céligny, Martin Barrett, Claude Berge, Beate Bittner, Axel Boehnke, Christine McIntyre, David MacDonald
| Article suivant Article suivant
  • Delivering maximum clinical benefit at an affordable price: engaging stakeholders in cancer care
  • Ronan J Kelly, Thomas J Smith

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.