S'abonner

3489 Virtual colography compared to endoscopic colonoscopy in detecting ascending colon and cecal lesions. - 20/03/14

Doi : 10.1016/S0016-5107(00)14189-6 
Mamoru Iimuro, Hajime Kuwayama, Yoshinori Kitazumi, Gordon Luk
 Univ Hosp at Koshigaya, Dokkyo Univ Sch of Med, Koshigaya, Japan. 

Résumé

Introduction: Virtual colography (VC) is being studied as a potential screening tool for colorectal polyps and cancers that is less invasive than endoscopic colonoscopy (EC). VC performance characteristics have been assessed only in small numbers of patients who had known lesions. The ascending colon and cecum are not visualized in up to 10% of EC.We therefore chose to evaluate the performance of VC, in compariosn with EC as a gold standard, in the ascending colon and cecum of all patients undergoing EC. Methods: Patients scheduled for EC for any reason were prospectively recruited for the study. 58 consecutive patients who agreed and gave informed consent were enrolled. EC was performed by a single gastroenterologist (12 yrs postgraduate) who was blinded as to VC results. All underwent VC immediately or within a week after EC, and the exams were done in separate areas of the hospital by different staff members. After standard EC prep, VC was performed with air insufflation to tolerance, and by single breath-hold thin section helical CT. GE Navigator software was used to generate interactive 3D images. Images were coded and in a blinded fashion. Results: 58 patients, mean age 58, range 31-83, and 72% were male. Reasons for EC were FOBT/rectal bleeding 49%, unexplained abdominal pain 11%, and others 40%. EC reached the cecum in 53/58 (91%). 26 polypoid lesions were detected, 12 were < 5mm, 8 were 5- 9 mm, 6 were >10 mm. 2 flat lesions were detected and confirmed on histology to be flat adenomas. Of the 26 polypoid lesions detected by EC, VC detected 11 (42%), 2/12 < 5mm (17%), 4/8 of 5-9 mm (50%), and 5/6 >10 mm (83%). VC detected 4 lesions not seen on EC, 0 < 5 mm, 2 of 5-9 mm, and 2 >10 mm. However, VC detected 0/2 of the flat adenomas seen on EC. Thus, overall sensitivity of VC was 42% (95% CI: 23%-63%) with 85% (95% CI: 66%- 96%) specificity. Conclusion: VC has comparable or higher sensitivity than EC for polypoid lesions >10mm, comparable sensitivity to EC for polypoid lesions of 5-9 mm, but has lower sensitivity for lesions < 5mm and for flat lesions. VC technology may need improvement for mucosal surface irregularity prior to wider acceptance. Nevertheless, the fact that malignant potential of colorectal polyps is clinically important generally only for polyps >10mm suggest that VC may have potential for routine clinical screening, especially in those patients in whom the ascending colon or cecum was not reached by EC.

Le texte complet de cet article est disponible en PDF.

© 2000  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 51 - N° 4P2

P. AB107 - avril 2000 Retour au numéro
Article précédent Article précédent
  • 3488 A prospective evaluation of endoscopic ultrasound-guided fine needle aspiration biopsy utilizing a new disposable 22 gauge fna needle device: results of diagnostic accuracy and complications from a large single center series.
  • Mohammed Barawi, Klaus Gottlieb, James H. Grendell, Frank G. Gress
| Article suivant Article suivant
  • 3490 Technical evaluation of two new biliary miniprobes for intraductal ultrasonography.
  • Bertrand Napoleon, Rosario Albis, Thierry Ponchon, Jacques Fumex, Bertrand Pujol, Jean Yves Scoazec, Jean Alain Chayvialle

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.