Whole Eye Axial Biometry During Accommodation Using Ultra-long Scan Depth Optical Coherence Tomography - 16/04/14

Abstract |
Purpose |
To investigate changes of whole eye axial biometry during accommodation using ultra-long scan depth optical coherence tomography (UL-OCT).
Design |
Prospective, observational case series.
Methods |
Twenty-one adult subjects were enrolled. Using UL-OCT, the left eye of each subject was imaged with relaxed diopters (0 D) and accommodative stimuli (+6 D). Full eye biometry included central corneal thickness (CCT), anterior chamber depth (ACD), lens thickness, vitreous length, and axial length (AL).
Results |
During accommodation (+6 D), the axial biometry of the whole eye changed significantly. Compared to the rest state, ACD at the accommodative state decreased significantly from 3.128 ± 0.305 mm to 2.961 ± 0.298 mm (paired t test, P < .001). The lens thickness increased significantly from 3.723 ± 0.237 mm to 3.963 ± 0.234 mm (P < .001). The vitreous length decreased significantly from 17.129 ± 0.864 mm to 17.057 ± 0.848 mm (P < .001). AL was 24.519 ± 0.917 mm at the rest state and increased to 24.545 ± 0.915 mm with +6 D accommodation stimulus. The elongated AL of 26.1 ± 13.4 μm between the rest and accommodative states was significant (P < .001).
Conclusions |
During accommodation, whole eye axial biometry changed, including a decrease in ACD and vitreous length and an increase in lens thickness and AL. UL-OCT provides an alternative method that is suitable for full eye biometry during accommodation.
Le texte complet de cet article est disponible en PDF.Plan
Vol 157 - N° 5
P. 1064 - mai 2014 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?