S'abonner

Single-Centre Experience with Perioperative Use of Intraaortic Balloon Pump in Cardiac Surgery - 07/05/14

Doi : 10.1016/j.hlc.2013.11.005 
Aslihan Kucuker , Levent Cetin, Seref Alp Kucuker, Mecit Gokcimen, Mete Hidiroglu, Aysegul Kunt, Fethi Saglam, Erol Sener
 Atatürk Training and Research Hospital, Cardiovascular Surgery Department, Ankara, Turkey 

?Corresponding author at: Atatürk Egitim ve Arastirma Hastanesi, Kalp ve Damar Cerrahisi Klinigi, 06530 Bilkent, Ankara, Turkey. Tel.: +90 505 243 3682; fax: +90 312 291 2705.

Résumé

Background

Intraaortic balloon pump (IABP) is frequently used in cardiac surgery in order to prevent or treat low cardiac output syndrome. Although being widely used and forming the first line therapy in these haemodynamically unstable patients despite maximal medication, optimal timing for IABP insertion is still discussed. This retrospective study evaluates hospital outcomes of patients receiving IABP at preoperative, intraoperative and postoperative periods during cardiac surgery.

Materials and methods

Between 2006 and 2012, 2196 patients underwent open cardiac surgery in our centre. IABP was used in 121 (5.4%) patients. Nine patients had preoperative IABP insertion, 76 patients (62.8%) had intraoperative insertion to ease weaning from cardiopulmonary bypass, and 36 patients (29.8%) had postoperative insertion in the intensive care unit mainly due to refractory haemodynamic instability. Hospital outcomes of these 121 patients were analysed retrospectively.

Results

The majority of the patients were male (men 89, 73.6% and women 32, 26.4%; mean age was 65.9±11.5 years). Among the cohort 87 (71.9%) underwent isolated coronary artery bypass surgery (CABG) and the rest (34 patients, 28.1%) were operated for valve disease with/without CABG or for CABG with carotid endarterectomy, left ventricular aneurysm repair, post myocardial infarction ventricular septal defect or pathologies involving ascending aorta. The overall hospital mortality of the whole cohort was 27.3%. Mortality rates according to IABP timing were 33.3%, 19.7% and 41.7% for pre, intra and postoperative insertion, respectively. Logistic regression analysis identified female gender, low ejection fraction (<30%), complex surgery and postoperative insertion as risk factors for mortality.

Conclusion

IABP insertion timing in cardiac surgery is crucial and many reports advocate early insertion since patient outcomes are poor for late insertions. This single centre study also confirms that the least favourable results are among patients with postoperative IABP insertion.

Le texte complet de cet article est disponible en PDF.

Keywords : Intraaortic balloon pump, Low cardiac output syndrome, Cardiac surgery, Circulatory support, Extrocorporeal balloon counterpulsation


Plan


? No external financial support exists for this study.


© 2013  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 5

P. 475-481 - mai 2014 Retour au numéro
Article précédent Article précédent
  • Comparison of Four Risk Scores for Contemporary Isolated Coronary Artery Bypass Grafting
  • Tom K.M. Wang, Acrane Y. Li, Tharumenthiran Ramanathan, Ralph A.H. Stewart, Greg Gamble, Harvey D. White
| Article suivant Article suivant
  • Right Ventricular Outflow Tract Enlargement Prior to Pulmonary Valve Replacement is Associated with Poorer Structural and Functional Outcomes, in Adults with Repaired Tetralogy of Fallot
  • Shamus O’Meagher, Madhusudan Ganigara, Phillip Munoz, David J. Tanous, Richard B. Chard, David S. Celermajer, Rajesh Puranik

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.