S'abonner

Usefulness of Left Ventricular Diastolic Function to Predict Recurrence of Atrial Fibrillation in Patients With Preserved Left Ventricular Systolic Function - 11/06/14

Doi : 10.1016/j.amjcard.2014.03.061 
Taishi Hirai, MD a, George Cotseones, DO a, Nader Makki, MD b, Anoop Agrawal, MD c, David J. Wilber, MD c, John T. Barron, MD, PhD c,
a Department of Medicine, Loyola University Chicago, Stritch School of Medicine, Loyola University Medical Center, Maywood, Illinois 
c Division of Cardiology, Department of Medicine, Loyola University Chicago, Stritch School of Medicine, Loyola University Medical Center, Maywood, Illinois 
b Department of Internal Medicine, University of Iowa, Iowa City, Iowa 

Corresponding author: Tel: (708) 327-2784; fax: (708) 327-2771.

Abstract

It is unknown whether recurrence of atrial fibrillation (AF) is related to severity of left ventricular diastolic dysfunction (LVDD) before ablation in patients with preserved left ventricular ejection fraction (LVEF). We tested the hypothesis that the presence and/or severity of LVDD before catheter ablation are related to AF recurrence during the 12-month follow-up period in patients with normal LVEF. We also aimed to determine what echocardiographic and Doppler indexes of LVDD before ablation are associated with recurrence of AF after ablation. We identified 198 patients with normal LVEF who underwent catheter ablation for AF with evidence of normal sinus rhythm within 1 year before ablation. The recurrence rate during 12-month follow-up period was assessed. Of the 198 patients, 76 patients (38%) had symptomatic recurrence and 122 patients (62%) had no recurrence. None of the independent variables, including mitral valve Doppler E and A peak velocities, E/A ratio, tissue Doppler e′ and a′ peak velocities, left atrial volume index, isovolumic relaxation time, and deceleration time, predicted recurrence. Patients with average E/e′ ratio >13, however, had increased recurrence (67% vs 35%, odds ratio 3.70, 95% confidence interval 1.21 to 11.3, p <0.05). In conclusion, there was no difference in the severity of LVDD using conventional echocardiographic indexes of LVDD in patients with or without recurrence of AF ablation. However, patients with average E/e′ ratio >13 did have an increased recurrence rate of AF at 12 months after procedure. Therefore, E/e′ ratio, indicative of increased left atrial pressure, may serve as a marker for AF recurrence after ablation.

Le texte complet de cet article est disponible en PDF.

Plan


 See page 69 for disclosure information.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 114 - N° 1

P. 65-69 - juillet 2014 Retour au numéro
Article précédent Article précédent
  • Long-Term Mortality Risk in Individuals With Atrial or Ventricular Premature Complexes (Results from the Third National Health and Nutrition Examination Survey)
  • Waqas Qureshi, Amit J. Shah, Taufiq Salahuddin, Elsayed Z. Soliman
| Article suivant Article suivant
  • Anticoagulant and Antiplatelet Therapy in Patients With Atrial Fibrillation Undergoing Percutaneous Coronary Intervention
  • Koji Goto, Kentaro Nakai, Satoshi Shizuta, Takeshi Morimoto, Hiroki Shiomi, Masahiro Natsuaki, Mitsuhiko Yahata, Chihiro Ota, Koh Ono, Takeru Makiyama, Yoshihisa Nakagawa, Yutaka Furukawa, Kazushige Kadota, Yoshiki Takatsu, Takashi Tamura, Akinori Takizawa, Tsukasa Inada, Osamu Doi, Ryuji Nohara, Mitsuo Matsuda, Teruki Takeda, Masayuki Kato, Manabu Shirotani, Hiroshi Eizawa, Katsuhisa Ishii, Jong-Dae Lee, Masaaki Takahashi, Minoru Horie, Mamoru Takahashi, Shinji Miki, Takeshi Aoyama, Satoru Suwa, Shuichi Hamasaki, Hisao Ogawa, Kazuaki Mitsudo, Masakiyo Nobuyoshi, Toru Kita, Takeshi Kimura, CREDO-Kyoto Registry Cohort-2 Investigators

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.