S'abonner

Ischemic Memory Imaging in Nonhuman Primates with Echocardiographic Molecular Imaging of Selectin Expression - 19/06/14

Doi : 10.1016/j.echo.2014.03.013 
Brian P. Davidson, MD , Scott M. Chadderdon, MD, J. Todd Belcik, BS, RCS, RDCS, Saurabh Gupta, MD, Jonathan R. Lindner, MD
 Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon 

Reprint requests: Brian P. Davidson, MD, Knight Cardiovascular Institute, Oregon Health & Science University, UHN 62, 3181 SW Sam Jackson Park Road, Portland, OR 97239.

Abstract

Background

Selectins are adhesion molecules that are expressed by the vascular endothelium upon activation and may be an imaging target for detecting myocardial ischemia long after resolution. The aim of this study was to test the hypothesis that molecular imaging of selectins with myocardial contrast echocardiographic (MCE) molecular imaging could be used to detect recent brief ischemia in closed-chest nonhuman primates.

Methods

Myocardial ischemia was produced in anesthetized adult rhesus macaques (n = 6) by percutaneous balloon catheter occlusion of the left anterior descending or circumflex coronary artery for 5 to 10 min. Three separate macaques served as nonischemic controls. MCE perfusion imaging was performed during coronary occlusion to measure risk area and at 100 to 110 min to exclude infarction. MCE molecular imaging was performed at 30 and 90 min after reperfusion using a lipid microbubble bearing dimeric recombinant human P-selectin glycoprotein ligand–1 (MB-YSPSL). Collection of blood for safety data, electrocardiography, and echocardiography were performed at baseline and before and 10 min after each MB-YSPSL injection.

Results

Vital signs, oxygen saturation, electrocardiographic results, ventricular systolic function, pulmonary vascular resistance, and serum safety markers were unchanged by intravenous injection of MB-YSPSL. On echocardiography, left ventricular dysfunction in the risk area had resolved by 30 min, and there was no evidence of infarction on MCE perfusion imaging. On selectin-targeted MCE molecular imaging, signal enhancement was greater (P < .05) in the risk area than remote territory at 30 min (25 ± 11 vs 11 ± 4 IU) and 90 min (13 ± 3 vs 3 ± 2 IU) after ischemia. There was no enhancement (<1 IU) in control nonischemic subjects.

Conclusions

In primates, MCE molecular imaging of selectins using MB-YSPSL, a recombinant ligand appropriate for humans, is both safe and effective for imaging recent myocardial ischemia. This technique may be useful for detecting recent ischemia in patients with chest pain even in the absence of necrosis.

Le texte complet de cet article est disponible en PDF.

Keywords : Molecular imaging, Contrast echocardiography, Ischemia, Selectins

Abbreviations : ACS, BP, CO, ECG, HR, LV, MCE, PSGL-1


Plan


 Dr Lindner is supported by grants R01-HL-078610, R01-DK-063508, R01HL111969, and RC1-HL-100659 from the National Institutes of Health (Bethesda, MD), and Dr Davidson is supported by grant T32-HL-094294-01 from the National Institutes of Health. Dr Chadderdon is supported by a Fellow-to-Faculty Transition Award from the American Heart Association (Dallas, TX).
 MB-YSPSL was manufactured and provided for this study by Bracco Imaging SA (Manno, Switzerland). There was no input from Bracco Imaging on study design, data analysis, or report preparation.
 Paul A. Grayburn, MD, served as Guest Editor for this report.


© 2014  American Society of Echocardiography. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 27 - N° 7

P. 786 - juillet 2014 Retour au numéro
Article précédent Article précédent
  • Detection of Coronary Artery Disease Using Coronary Flow Velocity Reserve by Transthoracic Doppler Echocardiography versus Multidetector Computed Tomography Coronary Angiography: Influence of Calcium Score
  • Kentaro Kakuta, Kaoru Dohi, Tomomi Yamada, Takashi Yamanaka, Masaki Kawamura, Shiro Nakamori, Hiroshi Nakajima, Takashi Tanigawa, Katsuya Onishi, Norikazu Yamada, Mashio Nakamura, Masaaki Ito
| Article suivant Article suivant
  • Superior Vena Cava Flow Is a Clinically Valid Measurement in the Preterm Newborn
  • Martin R. Kluckow, Nicholas J. Evans

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.