S'abonner

Direct electrical stimulation softens the cervix in pregnant and nonpregnant rats - 31/05/15

Doi : 10.1016/j.ajog.2015.01.042 
Dajun Fang, MD b, c, Shao-Qing Shi, MD a, b, Leili Shi, DDS a, Jinying Yang, MD b, c, Huishu Liu, MD, PhD b, c, Huimin Xia, MD b, c, Robert E. Garfield, PhD a, b,
a St Joseph’s Hospital and Medical Center, Phoenix, AZ 
b Guangzhou Women and Children’s Medical Center, Guangzhou, China 
c Southern Medical University, Guangzhou, China 

Corresponding author: Robert E. Garfield, PhD.

Abstract

Objective

The objective of the study was to determine the effects of electrical stimulation (ES) on cervical ripening in pregnant and nonpregnant rats.

Study Design

Timed pregnant and nonpregnant Sprague-Dawley rats (n = 6–7/group) were used. Cervical ES for pregnant rats was performed in vivo on day 15 of gestation by inserting an electrical probe into the vagina in contact with the cervix. Parameters of ES varied from 0.1 to 0.2 mA, 10 pulses per second, 20 milliseconds pulse duration, and repeating pulses for 15, 30, 60, and 120 minutes for pregnant ES groups and similar times for sham control groups with electrode but without ES. Nonpregnant ES groups were stimulated with only 0.2 mA for 30 minutes. Cervical collagen was measured in controls and following ES at various times using light-induced fluorescence (LIF) of collagen. Photographs were taken following ES, and some rats were killed, the cervices were isolated, and cervical extensibility was estimated.

Results

LIF values of pregnant rats are significantly lower ( P < .001) and extensibility greater ( P < .05) in the ES treatment groups compared with the control groups on days 16 and 17 of pregnancy. Similarly LIF is lower ( P < .05) and extensibility values greater ( P   <  .05) in nonpregnant rats treated with ES. No adverse effects, including altered delivery time, pup weights, or damage to cervix, were produced by low current levels of ES needed to soften the cervix.

Conclusion

The following conclusions were reached: (1) application of ES rapidly produces softening and ripening of the cervix in pregnant and nonpregnant rats; (2) ES treatment does not produce early delivery; (3) the exact mechanism for ES ripening is not yet known; and (4) ES might be used clinically to ripen the cervix when needed.

Le texte complet de cet article est disponible en PDF.

Key words : cervical ripening, cervix, electrical stimulation, induction of labor, parturition


Plan


  This study was supported by the Guangzhou Women and Children’s Medical Center , affiliated with Southern Medical University (H.X.) and St. Joseph’s Foundation (R.E.G.). Project sponsor (H.X.).
 The authors report no conflict of interest.
 Cite this article as: Fang D, Shi S-Q, Shi L, et al. Direct electrical stimulation softens the cervix in pregnant and nonpregnant rats. Am J Obstet Gynecol 2015;212:786.e1-9.


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 212 - N° 6

P. 786.e1-786.e9 - juin 2015 Retour au numéro
Article précédent Article précédent
  • Posterior axilla sling traction for shoulder dystocia: case review and a new method of shoulder rotation with the sling
  • Catherine Anne Cluver, G. Justus Hofmeyr
| Article suivant Article suivant
  • Efficacy of ultrasound-indicated cerclage in twin pregnancies
  • Amanda Roman, Burton Rochelson, Nathan S. Fox, Matthew Hoffman, Vincenzo Berghella, Vrunda Patel, Ilia Calluzzo, Gabriele Saccone, Adiel Fleischer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.