S'abonner

Operating theatre ventilation systems and microbial air contamination in total joint replacement surgery: results of the GISIO-ISChIA study - 06/06/15

Doi : 10.1016/j.jhin.2015.02.014 
A. Agodi a, F. Auxilia b, M. Barchitta a, M.L. Cristina c, D. D'Alessandro d, I. Mura e, M. Nobile b, C. Pasquarella f,
on behalf of the

Italian Study Group of Hospital Hygiene (GISIO)g

  Collaborators: Sergio Avondo, Patrizia Bellocchi, Rosario Canino, Claudio Capozzi, Renata Casarin, Massimo Cavasin, Pietro Contegiacomo, Maria Grazia Deriu, Francesco Roberto Evola, Pasquale Farsetti, Annise Grandi, Danilo Guareschi, Anna Maria Longhitano, Gianfranco Longo, Renzo Malatesta, Pietro Marenghi, Francesco Marras, Alessandra Maso, Anna Rita Mattaliano, Maria Teresa Montella, Umberto Moscato, Paola Navone, Maria Antonietta Romeo, Flora Rossi, Maria Ruffino, Carmela Santangelo, Marina Sartini, Giuseppe Sessa, Stefano Tardivo, Paolo Tranquilli Leali, Maria Valeria Torregrossa, Pietro Vitali.
Sergio Avondo, Patrizia Bellocchi, Rosario Canino, Claudio Capozzi, Renata Casarin, Massimo Cavasin, Pietro Contegiacomo, Maria Grazia Deriu, Francesco Roberto Evola, Pasquale Farsetti, Annise Grandi, Danilo Guareschi, Anna Maria Longhitano, Gianfranco Longo, Renzo Malatesta, Pietro Marenghi, Francesco Marras, Alessandra Maso, Anna Rita Mattaliano, Maria Teresa Montella, Umberto Moscato, Paola Navone, Maria Antonietta Romeo, Flora Rossi, Maria Ruffino, Carmela Santangelo, Marina Sartini, Giuseppe Sessa, Stefano Tardivo, Paolo Tranquilli Leali, Maria Valeria Torregrossa, Pietro Vitali

a Department of Medical and Surgical Sciences and Advanced Technologies “GF Ingrassia”, University of Catania, Catania, Italy 
b Department of Biomedical Sciences for Health, University of Milan, Milan, Italy 
c Department of Health Sciences, University of Genoa, Genoa, Italy 
d Department of Civil Building and Environmental Engineering, ‘Sapienza’ University, Rome, Italy 
e Department of Biomedical Sciences, University of Sassari, Sassari, Italy 
f Department of Biomedical, Biotechnological and Translational Sciences, University of Parma, Parma, Italy 

Corresponding author. Address: Department of Biomedical, Biotechnological and Translational Sciences, Unit of Public Health, University of Parma, Via Volturno, 39, 43125 Parma, Italy. Tel.: +39 0521 903793; fax: +39 0521 903832.

Summary

Background

Recent studies have shown a higher rate of surgical site infections in hip prosthesis implantation using unidirectional airflow ventilation compared with turbulent ventilation. However, these studies did not measure the air microbial quality of operating theatres (OTs), and assumed it to be compliant with the recommended standards for this ventilation technique.

Aim

To evaluate airborne microbial contamination in OTs during hip and knee replacement surgery, and compare the findings with values recommended for joint replacement surgery.

Methods

Air samplings were performed in 28 OTs supplied with unidirectional, turbulent and mixed airflow ventilation. Samples were collected using passive sampling to determine the index of microbial air contamination (IMA). Active sampling was also performed in some of the OTs. The average number of people in the OT and the number of door openings during the sampling period were recorded.

Findings

In total, 1228 elective prosthesis procedures (60.1% hip and 39.9% knee) were included in this study. Of passive samplings performed during surgical activity in unidirectional airflow ventilation OTs (U-OTs) and mixed airflow OTs (M-OTs), 58.9% and 87.6% had IMA values >2, respectively. Of samplings performed during surgical activity in turbulent airflow OTs (T-OTs) and in turbulent airflow OTs with the surgical team wearing Steri-Shield Turbo Helmets (TH-OTs), 8.6% and 60% had IMA values ≤2, respectively. Positive correlation was found between IMA values and the number of people in the OT and the number of door openings (P < 0.001). In addition, correlation was found between active and passive sampling (P < 0.001).

Conclusion

These findings challenge the belief that unidirectional systems always provide acceptable airborne bacterial counts.

Le texte complet de cet article est disponible en PDF.

Keywords : Air microbial contamination, Total joint replacement, Operating theatre, Heating, ventilation and air conditioning


Plan


© 2015  The Healthcare Infection Society. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 90 - N° 3

P. 213-219 - juillet 2015 Retour au numéro
Article précédent Article précédent
  • Detection of Escherichia coli sequence type 131 by matrix-assisted laser desorption ionization time-of-flight mass spectrometry: implications for infection control policies?
  • J. Lafolie, M. Sauget, N. Cabrolier, D. Hocquet, X. Bertrand
| Article suivant Article suivant
  • Hand-touch contact assessment of high-touch and mutual-touch surfaces among healthcare workers, patients, and visitors
  • V.C.C. Cheng, P.H. Chau, W.M. Lee, S.K.Y. Ho, D.W.Y. Lee, S.Y.C. So, S.C.Y. Wong, J.W.M. Tai, K.Y. Yuen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.