Abbonarsi

0014: Feasibility, image quality and radiation dose of Coronary CT Angiography (CCTA) in obese patients using a new generation 256 Multi-Detector CT (MDCT) - 12/02/16

Doi : 10.1016/S1878-6480(16)30054-4 
Laurent Macron , Jacques Feignoux, Jean-Louis Sablayrolles
 Centre Cardiologique du Nord, Saint-Denis, France 

*Corresponding author:

Riassunto

Introduction

To evaluate feasibility, image quality and radiation dose of CCTA in obese patients using new generation 256-MDCT.

Methods and materials

Thirty consecutive obese patients (Body Mass Index (BMI)>30) undergoing CCTA on a 256-MDCT (Revolution CT, General Electric) were retrospectively included. Prevalence and impact on diagnosis of motion and step artifacts were independently evaluated by two experienced readers using a 3-point scale (0: no artifact; 1: artifacts without interference on diagnosis; 2: artifacts interfere with diagnosis) and percentage of assessable coronary segments was calculated. Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were measured for quantitative assessment. Radiation dose was evaluated by calculating the mean effective dose (ED).

Results

Mean BMI was 36.0±5.9kg/m 2 with a mean HR of 91.4.0±48.9 bpm. Mean injected contrast volume (Iohexol 350) was 73.0±11.2mL. On a per-patient analysis, all the coronary segments were assessable in 29 (97%) patients. Only 2 coronary segments were not assessable in 1 patient due to motion arte-facts resulted in a coronary segments assessability of 99.6% (455/457 segments) in the overall population. No step artifact was observed whereas motion arte-facts (3-point scale score of 0.27±0.9) were infrequent and do not interfere with diagnosis. The mean CNR and mean SNR were respectively 10.0±2.6 and 11.1±2.0. ED remains low with an average of 2.71±1.6 mSv.

Conclusion

CCTA is feasible in obese patients using a new generation 256-MDCT providing good image quality and low radiation dose in this challenging population.

Il testo completo di questo articolo è disponibile in PDF.

© 2016  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 8 - N° 1

P. 18 - gennaio 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • 0256: Accuracy of visual estimation compared to objective anatomical and functional measurement, QCA and FFR, in coronary lesions
  • Julien Adjedj, Gabor Toth, Guiseppe Di Gioia, Angela Ferrara, Vincent Flore, Mariano Pellicano, Emanuele Barbato, William Wijns, Bernard de Bruyne
| Articolo seguente Articolo seguente
  • 0012: Comparison of Coronary CT Angiography (CCTA) for patients with high heart rates using a new generation 256 Multi-Detector CT (MDCT) and a 64-MDCT: image quality and radiation dose
  • Laurent Macron, Jean-Louis Sablayrolles, Jacques Feignoux

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.