Abbonarsi

Dosage du baclofène dans le plasma en chromatographie phase liquide couplée à de la spectrométrie de masse en tandem : à propos d’un cas de surdosage - 18/08/16

Doi : 10.1016/j.toxac.2016.04.001 
Laurence Labat a, , b , Antonio Goncalves a, Cédric Cleophax c, Bruno Megarbane b, d, Xavier Decleves a, b
a Biologie du médicament et toxicologie, groupe COCHIN, Assistance publique–Hôpitaux de Paris, 27, rue du Faubourg Saint-Jacques, 75014 Paris cedex, France 
b Inserm, variabilité de réponse aux psychotropes, UMR-S1144, faculté de pharmacie Paris Descartes, universités Paris Descartes–Paris Diderot, 4, rue de l’Observatoire, 75004 Paris, France 
c Réanimation polyvalente, CH René-Dubos, 6, avenue de l’Île-de-France, 95300 Pontoise, France 
d Réanimation médicale et toxicologique, hôpital Lariboisière, Assistance publique–Hôpitaux de Paris, 2, rue Ambroise-Paré, 75010 Paris, France 

Auteur correspondant.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 7
Iconografia 3
Video 0
Altro 0

Résumé

Le baclofène, myorelaxant d’action centrale utilisé pour ses propriétés antispasmodiques, est devenu un traitement d’intérêt dans l’alcoolo-dépendance. Nous décrivons une nouvelle méthode de dosage du baclofène dans le plasma en chromatographie liquide couplée à de la spectrométrie de masse en tandem avec une simple préparation d’échantillon par une étape de précipitation, en présence d’un étalon interne baclofène-d4. La méthode est décrite en mode gradient avec de l’eau et de l’acétonitrile en présence de 0,1 % d’acide formique sur une colonne de type Accucore PFP®. La détection est réalisée en spectrométrie de masse en tandem en mode d’ionisation électrospray positif avec des transitions de quantification m/z 213,9/196,9 pour le baclofène et 217,9/200,9 pour le baclofène-d4. La méthode de dosage est validée dans le plasma selon les normes de l’European Medicines Agency (EMA) avec une réponse linéaire entre 10 et 2000μg/L (r2>0,999) et des reproductibilités et précisions<11,5 %. Cette méthode de dosage développée pour le suivi des patients traités pour leur alcoolo-dépendance a également été utilisée pour le suivi de patients arrivant aux urgences avec un surdosage en baclofène. Nous rapportons le cas d’une patiente âgée de 29ans, ayant ingéré une dose supposée de 3500mg de baclofène pour laquelle le suivi des concentrations plasmatiques a mis en évidence les difficultés d’élimination du baclofène par les séances d’hémodialyse.

Il testo completo di questo articolo è disponibile in PDF.

Summary

Baclofen, a centrally acting gamma-aminobutyric acid indicated to treat spasticity of spinal cord origin, is increasingly used to manage alcohol dependence. We described a new method to determine baclofen in plasma by liquid chromatography coupled to mass spectrometry in tandem with a very simple sample preparation with one-step protein precipitation using internal standard baclofen-d4. A gradient of mobile phase with water and acetonitrile (0.1% formic acid) was used on an Accucore PFP® column. Mass spectrometry was performed in positive ionization electrospray mode with quantification transitions m/z 213.9/196.9 for baclofen and 217.9/200.9 for baclofen-d4. The method was validated in plasma according to the European Medicines Agency (EMA) guidelines with a linear response for concentrations ranged between 10 and 2000μg/L (r2>0.999) and precisions and accuracies below 11.5%. This method was developed for monitoring plasma baclofen levels and was successfully applied to patients with baclofen intoxication. We report a case study of a 29-year-old woman admitted to intensive care unit after ingesting a dose supposed of 3500mg of baclofen. Plasma monitoring appears beneficial for guiding baclofen elimination and explains the contribution of hemodialysis.

Il testo completo di questo articolo è disponibile in PDF.

Mots clés : Baclofène, LCMSMS, Validation, Intoxication

Keywords : Baclofen, LCMSMS, Validation, Intoxication


Mappa


© 2016  Société Française de Toxicologie Analytique. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 28 - N° 3

P. 211-217 - settembre 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Les sels QuEChERS pour l’identification et la quantification de benzodiazépines et métabolites dans les prélèvements biologiques par LC–MS/MS
  • Lauranne Poncelet, Souleiman El Bakhi, Sylvain Dulaurent, Franck Saint-Marcoux
| Articolo seguente Articolo seguente
  • Intoxication à l’acide fluorhydrique (HF) : doser le calcium ionisé
  • Régis Bédry, Sophie Gromb-Monnoyeur

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.