Abbonarsi

Comparaison de trois méthodes d'impédancemétrie bioélectrique et de l'anthropométrie pour estimer la composition corporelle des malades de réanimation soumis à une ventilation mécanique - 01/01/01

Christophe  Faisy,  Antoine  Rabbat,  Basile  Kouchakji,  Marie-France  Doré,  Jean Pierre  Laaban * *Correspondance et tirés à part.

Mostrare le affiliazioni

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 9
Iconografia 0
Video 0
Altro 0

Riassunto

Le but de l'étude était de comparer la masse maigre mesurée par trois techniques d'impédancemétrie bioélectrique à celle calculée par anthropométrie chez des patients en insuffisance respiratoire aiguë nécessitant une ventilation mécanique.

Patients et méthodes - Soixante-dix patients consécutifs ont été inclus. La masse maigre a été calculée à partir de la mesure de l'épaisseur de quatre plis cutanés (MM-ant) et mesurée par trois techniques d'impédancemétrie : deux électrodes piquées et deux fréquences (5 kHz et 1 Mhz) (MM-Thomasset), quatre électrodes collées et deux fréquences (5 et 100 kHz) (MM-5/100) ou quatre électrodes collées et une fréquence (50 kHz). Pour cette dernière technique, nous avons utilisé les équations de l'appareil (MM-50) et l'équation de Kyle (MM-kyle). Les masses maigres mesurées par impédancemétrie et la MM-ant ont été comparées par régression linéaire simple et par la méthode de Bland et Altman.

Résultats - La technique de Thomasset et celle à 50 kHz avec l'équation de l'appareil donnent des masses maigres comparables (respectivement   kg et  ) mais différentes des techniques à 4 électrodes collées avec 5 et 100 kHz (  kg) ou avec 50 kHz et l'équation de Kyle (  kg). Les corrélations entre anthropométrie et impédancemétrie semblent plus étroites entre MM-ant et MM-Thomasset ou MM-kyle (  et 0,77 respectivement) qu'entre MM-ant et MM-5/100 ou MM-50 (  et 0,73 respectivement). Cependant, l'analyse de concordance montre une congruence médiocre entre l'anthropométrie et les techniques bioélectriques.

Conclusion - Cette étude suggère que les trois techniques d'impédancemétrie donnent des résultats discordants et devraient être validées contre une technique de référence chez les patients en insuffisance respiratoire aiguë.

Mots clés  : anthropométrie ; composition corporelle ; impédancemétrie bioélectrique ; nutrition ; réanimation.

Abstract

The aim of the present study was to compare the fat-free mass measured by three techniques of bioelectrical impedance with that obtained by anthropometry in critically ill patients requiring artificial ventilation.

Patients and methods - Seventy patients were consecutively enrolled. Fat-free mass was determined from the measurement of four skinfold thicknesses (FFM-ant) and using three techniques of bioelectrical impedance: two subcutaneous electrodes and two frequencies (5 kHz and 1 MHz) (FFM-Thomasset), four surface electrodes and two frequencies (5 et 100 kHz) (FFM-5/100), and four surface electrodes and one frequency (50 kHz) using either the manufacturor equation (FFM-50) or those of Kyle (FFM-Kyle). Fat-free masses obtained by biolectrical impedance and FFM-ant were compared by simple linear regression and the method of Bland and Altman.

Results - Fat-free masses measured using the 2-electrode 2-frequency or using the 4-electrode 1-frequency techniques were comparable (  and   kg, respectively) but significantly different from those obtained using the 4-electrode 2-frequency (  kg) or using the 4-electrode 1-frequency (with Kyle's equation) techniques (  kg). Correlation coefficients between FFM-ant and FFM-Thomasset or FFM-Kyle (  and 0.77, respectively) were higher than between FFM-ant and FFM-5/100 or FFM-50 (  and 0.73, respectively). However, the results obtained by anthropometry were not in line with those obtained by bioelectrical impedance techniques.

Conclusion - This study suggests that the three techniques of biolectrical impedance yield discordant results and should be validated by comparison with a reference method in patients with acute respiratory failure.

Mots clés  : anthropometry ; bioelectrical impedance analysis ; body composition ; intensive care unit ; nutrition.

Mappa



© 2001  Éditions scientifiques et médicales Elsevier SAS. Tutti i diritti riservati.

Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 15 - N° 2

P. 115-123 - 2001 Ritorno al numero
Articolo precedente Articolo precedente
  • Évaluation du risque de contamination bactériologique d'une solution de nutrition entérale au cours d'une administration discontinue
  • Lo.nulluml;c Simon, Nadine. Gaconnet, Franck. Arnaud-Battandier, Philippe. Hartemann
| Articolo seguente Articolo seguente
  • L'alimentation préhistorique : alimentation de demain ?
  • Jacques di Costanzo

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.