Abbonarsi

Endoscopic string clip suturing method: a prospective pilot study (with video) - 22/03/18

Doi : 10.1016/j.gie.2017.11.007 
Toshihiro Nishizawa, MD, PhD 1, 2, Teppei Akimoto, MD 1, Toshio Uraoka, MD, PhD 1, 3, Yutaka Mitsunaga, MD 1, Tadateru Maehata, MD, PhD 1, Yasutoshi Ochiai, MD, PhD 1, Ai Fujimoto, MD, PhD 1, Osamu Goto, MD, PhD 1, Takanori Kanai, MD, PhD 2, Naohisa Yahagi, MD, PhD 1,
1 Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Tokyo, Japan 
2 Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Tokyo, Japan 
3 Division of Gastroenterology, National Hospital Organization Tokyo Medical Center, Toky, Japan 

Reprint requests: Naohisa Yahagi, MD, PhD, Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.Division of Research and Development for Minimally Invasive TreatmentCancer CenterKeio University School of Medicine35 ShinanomachiShinjuku-kuTokyo 160-8582Japan

Abstract

Background and Aims

We developed a suturing method with string and clips for a single-channel endoscope. The feasibility of the string clip suturing method is evaluated in this prospective pilot study.

Methods

This study involved 10 consecutive patients who underwent endoscopic submucosal dissection (ESD) for a duodenal tumor. Polyester string was tied to the arm of a partially out thrust clip. The clip and string can be passed through the instrument channel (3.2 mm) of a single-channel endoscope. The clip with string was placed at the distal edge of the large mucosal defect. A second clip was hooked on the string and placed on the opposite side. Both clips were gathered by pulling the free end of the string, and additional clips were placed to achieve complete closure. This method was compared with that for the previous 10 patients without mucosal closure after duodenal ESD.

Results

Mean size of resected specimens was 39.1 ± 12.4 mm. The success rate of the string clip suturing method was 100% (10/10). The mean procedure time was 23.4 ± 13.8 minutes. Perforation during ESD occurred in 1 patient and was successfully closed by this method. None of the treated patients developed serious adverse events after the procedure. Compared with the no-suture group, the length of stay was significantly shorter (P = .038).

Conclusion

The string clip suturing method appears to be a safe and effective method for closure of large mucosal defects. (Clinical trial registration number: UMIN000023698.)

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : ESD, OTCS


Mappa


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Yahagi at yahagi.keio@gmail.com.


© 2018  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 87 - N° 4

P. 1074-1078 - aprile 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Self-expandable metal stents in malignant biliary obstruction: Back to the roots with uncovered stents as the “new” standard?
  • Torsten Beyna, Horst Neuhaus
| Articolo seguente Articolo seguente
  • The role of colorectal endoscopic submucosal dissection in patients with ulcerative colitis
  • Satoshi Kinoshita, Toshio Uraoka, Toshihiro Nishizawa, Makoto Naganuma, Yasushi Iwao, Yasutoshi Ochiai, Ai Fujimoto, Osamu Goto, Masayuki Shimoda, Haruhiko Ogata, Takanori Kanai, Naohisa Yahagi

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.