The routine use of a 64 kb/sec Numeris network requires that a compromise be reached between image quality and time required for image transfer. Our goal was to present our experience and describe our choices when reporting examinations for two geriatric hospitals located at a short distance from our radiology department. Different digitization parameters were tested (resolution, compression) for 10 plain films corresponding to the usual clinical situations: abdominal X ray, chest X ray, wrist, spine and pelvis X rays. A subjective analysis of the global quality and of the quality of a region of interest enlarged twelve times has been performed. After result analysis, our choices were: digitization using 75 or 150 DPI and systematic use of a reversible compression format. This system proved satisfactory for both clinicians and radiologists; since its implementation, 1 800 files have been reviewed.

L'utilisation en routine du réseau Numéris à 64 kbits/s nécessite de trouver un compromis acceptable entre la qualité des images numérisées et les temps de transfert. Le but de ce travail est de rapporter notre expérience et de présenter nos choix dans le cadre d'une assistance au diagnostic pour deux établissements de personnes âgées délocalisés par rapport au service d'imagerie. Nous avons fait varier les paramètres de numérisation (résolution, compression) pour dix clichés représentant l'activité des antennes : abdomen sans préparation, radiographie pulmonaire, radiographies de poignet, de rachis et de bassin. Une analyse subjective de la qualité globale et d'une région d'intérêt agrandie 12 fois, a été réalisée. Les résultats de cette analyse nous ont permis de proposer les choix suivants. Les clichés sont numérisés en 75 ou 150 DPI et une compression réversible est utilisée systématiquement. Ce système donne entière satisfaction aux médecins gériatres et à l'équipe de radiologie, depuis sa mise en place, 1 800 dossiers ont été analysés.


Mots clés : Téléradiologie. , Numérisation d'images. , Qualité d'images.

Keywords: Teleradiology. , Digitization. , Image quality.


Mappa



© 1999 Elsevier Masson SAS. Tous droits réservés.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 80 - N° 9

P. 954 - settembre 1999 Ritorno al numero
Articolo precedente Articolo precedente
  • QUID ?
  • A El Quessar, S Brique, A Destee, Jp Pruvo
| Articolo seguente Articolo seguente
  • COMPTE RENDU

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.