Abbonarsi

Simulated internal jugular vein cannulation using a needle-guiding device - 15/10/18

Doi : 10.1016/j.ajem.2018.02.012 
Ji Hoon Kim, MD, MPH a, Jin Ha Park, MD, PhD b, Junho Cho, MD, PhD a, Tae Young Kong, MD a, Ji Hwan Lee, MD a, Jin Ho Beom, MD a, Young Seon Joo, MD a, Dong Ryul Ko, MD a, Hyun Soo Chung, MD, PhD a,
a Department of Emergency Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea 
b Department of Anesthesiology and Pain Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemoon-gu, Seoul 03722, Republic of Korea 

Corresponding author.

Abstract

Background

Using a two-dimensional ultrasound-guided approach does not guarantee success during the first attempt at internal jugular vein cannulation. Our randomized, parallel simulation study examined whether a new disposable device could improve the success rate of the first attempt at ultrasound-guided internal jugular vein cannulation of a simulated internal jugular vein.

Methods

Eighty-eight participants were randomized to perform needle insertion for internal jugular vein cannulation of a phantom using the ultrasound-guided approach with (case group) or without (control group) this new device. The primary outcome was the success rate of the first attempt. The secondary outcome was the frequency of mechanical complications such as arterial puncture and posterior wall puncture, procedure time, and level of difficulty.

Results

Among 44 participants using the device, 33 (75.0%) achieved successful cannulation on the first attempt. However, only 12 (27.3%) of the 44 participants not using the device recorded success during the first attempt (risk difference, 0.477; 95% confidence interval [CI] 0.294–0.661; P<0.001). The number of attempts was significantly lower (risk difference, −3.955; 95% CI, −5.014 to −3.712; P<0.001) when participants performed cannulation with the device (1.63±1.71) than without the device (5.59±5.78). Our study also showed that participants were comfortable when performing the ultrasound-guided approach with the new device (risk difference, −1.955; 95% CI, −2.016 to −1.493; P<0.0001).

Conclusions

The new disposable device was effective for successful first attempts at needle insertion during ultrasound-guided internal jugular vein cannulation. Future clinical trials are needed to assess the effectiveness of this device.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Ultrasound, Internal jugular vein, Cannulation, Device


Mappa


© 2018  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 36 - N° 11

P. 1931-1936 - novembre 2018 Ritorno al numero
Articolo precedente Articolo precedente
  • Info for authors
| Articolo seguente Articolo seguente
  • Concomitant external and internal hemorrhage: Challenges to managing patients with open pelvic fracture
  • Chih-Yuan Fu, Ruo-Yi Huang, Shang-Yu Wang, Chien-Hung Liao, Jen-Fu Huang, Yu-Pao Hsu, Chia-Yun Lin, Shih-Ching Kang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.