Abstract

Objectives

There are limited non-invasive methods to assess lower extremity arterial injuries in the emergency department (ED) and pre-hospital setting. The ankle-brachial index (ABI) requires careful auscultation by Doppler, an approach made difficult in noisy environments. We sought to determine the agreement of the ABI measured using the pulse oximeter plethysmograph waveform (Pleth) with auscultation by Doppler in a controlled setting. A secondary outcome sought to examine the agreement of ABI by automated oscillometric sphygmomanometer (AOS) with Doppler.

Methods

We measured blood pressure in the right upper and lower extremities of healthy volunteers using: (1) Doppler and manual sphygmomanometer; (2) Pleth and manual sphygmomanometer; and (3) AOS. The Bland-Altman approach to assessing agreement between methods was used comparing mean differences between ABI pairs to their means for Doppler versus Pleth and Doppler versus AOS. The intraclass correlation coefficient (ICC) from mixed effects models examined intra- and inter-rater reliability.

Results

Among 100 participants with normal ABI the mean ABI (95%CI) were Doppler 1.11 (0.90–1.33), Pleth 1.10 (0.91–1.30), and AOS 1.10 (0.90–1.30). The ABI difference (95% CI for limits of agreement) were 0.01 (−0.20,0.18) for Doppler-Pleth and 0.02 (−0.26, 0.22) for Doppler-AOS. The ICC for the Doppler-Pleth comparison (ICC = 0.56, 95% CI 0.47–0.63) was greater than for the Doppler-AOS (ICC = 0.32, 95% CI 0.19–0.43).

Conclusions

The ABI measured using the Pleth has a high level of agreement with measurement by Doppler. The AOS and Doppler have good agreement with greater measurement variability. Pleth and AOS may be reasonable alternatives to Doppler for ABI.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Ankle-brachial index, Pulse oximetry, Plethysmography, Vascular sufficiency


Mappa


© 2020  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 40

P. 162-165 - febbraio 2021 Ritorno al numero
Articolo precedente Articolo precedente
  • Estimating maximum patient throughput at an ED scanner: Is three patients per hour the magic number?
  • Bryan A. Stenson, Joshua W. Joseph, Peter S. Antkowiak, Robin B. Levenson, David T. Chiu, Leon D. Sanchez
| Articolo seguente Articolo seguente
  • Injury rates per mile of travel for electric scooters versus motor vehicles
  • Kevin Rix, Nora J. Demchur, David F. Zane, Lawrence H. Brown

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.