Abbonarsi

Association Between Fluid Volume in Inner Nuclear Layer and Visual Acuity in Diabetic Macular Edema - 18/04/22

Doi : 10.1016/j.ajo.2021.12.012 
Kotaro Tsuboi 1, Qi Sheng You 1, 2, Yukun Guo 1, Jie Wang 1, 3, Christina J. Flaxel 1, Steven T. Bailey 1, David Huang 1, Yali Jia 1, 3, Thomas S. Hwang 1,
1 From the Casey Eye Institute (K.T., Q.S.Y., Y.G., J.W., C.J.F., S.T.B., D.H., Y.J., T.S.H.), Oregon Health and Science University, Portland, Oregon, USA 
2 Kresge Eye Institute (Q.S.Y.), Detroit Medical Center, Wayne State University, Detroit, Michigan, USA 
3 Department of Biomedical Engineering (J.W., Y.J.), Oregon Health & Science University, Portland, Oregon, USA 

Inquiries to Thomas S. Hwang, Casey Eye Institute, Oregon Health & Science University, 515 SW Campus Dr, Portland, OR 97239, USA.Casey Eye InstituteOregon Health & Science University515 SW Campus DrPortlandOR97239USA

Riassunto

PURPOSE

In diabetic macular edema (DME), the correlation between visual acuity (VA) and central subfield thickness (CST) is weak. We hypothesize that fluid volume (FV) in the inner nuclear layer (INL) may correlate more strongly with VA.

DESIGN

Retrospective, cross-sectional study.

METHODS

One eye each of diabetic patients with DME was included. We measured intraretinal fluid volume that was detected by automated fluid detection algorithm on 3- × 3-mm optical coherence tomography angiogram volume scans. The detected fluid was subdivided into inner FV, bounded by the INL, and outer FV, the fluid between the outer border of INL to the ellipsoid zone.

RESULTS

We enrolled 125 patients with DME (60 women; mean age, 61 years). The mean detected inner FV was 0.013 mm3 in 109 eyes (87%). The mean detected outer FV was 0.042 mm3 in 124 eyes (99%). Univariate analysis demonstrated that the VA significantly correlated with the inner FV (P < .0001), whole macular FV (P = .010), and CST (P = .036). Multivariate analysis demonstrated that the inner FV was the only significant factor (β = −0.41, P = .004). These correlations were consistent when the treatment-naïve group (n = 33) and the eyes without previous laser treatments (n = 93) were analyzed separately. The area under the receiver operating characteristic curve of inner FV for VA of 20/32 or worse was significantly higher than that for CST (0.66 vs 0.54, P = .018).

CONCLUSIONS

The inner FV has a stronger association with VA than other OCT biomarkers in DME and may be more clinically useful.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Supplemental Material available at AJO.com.


© 2021  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 237

P. 164-172 - maggio 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Comparing Five Criteria for Evaluating Glaucomatous Visual Fields
  • Herman Stubeda, Jack Quach, Jennifer Gao, Lesya M. Shuba, Marcelo T. Nicolela, Balwantray C. Chauhan, Jayme R. Vianna
| Articolo seguente Articolo seguente
  • Recovery of Vision after Optic Nerve Sheath Fenestration in Children and Adolescents with Elevated Intracranial Pressure
  • DAPHNA LANDAU PRAT, GRANT T. LIU, ROBERT A. AVERY, GUI-SHUANG YING, YINENG CHEN, LAUREN A. TOMLINSON, KAREN E. REVERE, JAMES A. KATOWITZ, WILLIAM R. KATOWITZ

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.