Abbonarsi

Proximal humeral bone defect in reverse shoulder arthroplasty combined with latissimus-dorsi transfer is not related with a poor outcome - 15/05/22

Doi : 10.1016/j.otsr.2022.103263 
Philippe Valenti a, Frantzeska Zampeli b, Giovanni Caruso c, Imen Nidtahar a, Natalia Martinez-Catalan a, d, Efi Kazum e,
a Paris Shoulder Unit, Clinique Bizet, 22, rue Georges-Bizet, 75116 Paris, France 
b Hand-Upper Limb-Microsurgery Department, General Hospital KAT, Athens, Greece 
c Shoulder Unit, Koelliker Hospital, Corso Galileo Ferraris 247/255, 10134 Turin, Italy 
d Hospital Fundación Jiménez Diaz, Madrid, Spain 
e Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Weizmann St 6, 6423906, Tel Aviv, Israel 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Reverse total shoulder arthroplasty (RSA) associated with modified L’Episcopo (isolated LD) or L’Episcopo (combined TM and LD) procedures had been confirmed to effectively overcome the expected external rotation deficit in patient with postero-superior massive cuff tear and teres minor deficiency. The objective of this study was to evaluate the radiological bony lesions of the lateral proximal humerus following RSA combined with tendon transfer, and to determine whether these bony lesions affect the clinical outcome.

Material and methods

A retrospective review of 24 RSAs (mean age 68.71 years, range 52–83) associated with modified L’Episcopo procedure (9) and L’Episcopo procedure (15) was performed. X-rays were assessed for lateral cortex lesions and were categorized into either intact, irregular or complete lytic appearances. In addition, signs of stem loosening were assessed. Clinical outcome measures included range of motion, SSV, VAS, and Constant-Murley scores.

Results

With a mean follow-up of 44.71 months (12–97; SD 27.42), eight (33.3%) patients demonstrated intact lateral cortex, eight (33.3%) irregular and eight (33.3%) lytic lesions. 40% of cemented stems demonstrated a deformed cortex compared to 74% of cementless stems. Radiolucent lines were detected in one cemented stem (p=0.046). GT resorption (p=0.147), condensations lines (p=0.449) and spot weld (p=0.342), appeared exclusively in non-cemented stem. Postoperatively all patients (24) demonstrated significant improvements in all clinical and functional parameters. A comparison between patient with (Group 2, 16 patients) and without bony lesions (Group 1, 8 patients) revealed no significant differences in functional scores and range of motion: Constant (p=0,61), VAS (p=0,61), SSV (p=0,66) and external rotation (p=0,34).

Conclusion

At short-term follow-up, RSA combined with L’Episcopo or modified l’Episcopo procedure resulted in high incidence (67%) of lateral proximal humerus lesions. Radiolucent lines were noted in cemented stems whereas, signs of stress shielding and GT resorption appeared in non-cemented stems. Yet, no case of humeral loosening was detected and these lesions did not seem to affect the clinical outcome. The use of cemented straight standard-length humeral stems should be positively considered in RSA associated with LD\TM tendon transfer.

Level of evidence

IV; retrospective study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Tendon transfer, Reverse shoulder arthroplasty, L’Episcopo, External rotation, Radiological outcome, Bone lesion


Mappa


© 2022  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 108 - N° 3

Articolo 103263- maggio 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Assessment of intraoperative bleeding in reverse shoulder arthroplasty – with or without a stem
  • Fiona Sakek, Harrison Haight, Pierre Tuphé, Inès Regas, Antoine Adam, Séverin Rochet, Tristan Lascar, Laurent Obert, François Loisel
| Articolo seguente Articolo seguente
  • Retraction notice to “Flexor Digitorum Superficialis tendon transfer for a long-standing boutonniere deformity finger- a retrospective study of 11 cases” [Orth Trauma Surg Res 107 (2021) 102971]
  • Jose Jerome Terrence

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.