Which method for femoral component sizing when performing kinematic alignment TKA? An in silico study - 23/03/24

Doi : 10.1016/j.otsr.2023.103769 
Fasen Huang a, b, Simon Harris a, Tianyu Zhou a, Gabriel B. Roby c, Benjamin Preston d, Charles Rivière a, c, e,
a MSK laboratory, Department of Surgery and Cancer, Imperial College London, London W12 0BZ, United Kingdom 
b Shenzhen Traditional Chinese Medicine Hospital, Shenzhen 518033, China 
c Bordeaux Arthroplasty Research Institute, 6, rue Georges-Negrevergne, 33700 Mérignac, France 
d Imperial College London School of Medicine, South Kensington Campus, London SW7 2DD, United Kingdom 
e Clinique du Sport Bordeaux-Mérignac, 4, rue Georges-Negrevergne, 33700 Mérignac, France 

*Corresponding author. MSK laboratory, Department of Surgery and Cancer, Imperial College London, London W12 0BZ, United Kingdom.MSK laboratory, Department of Surgery and Cancer, Imperial College LondonLondonW12 0BZUnited Kingdom

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

The kinematically alignment (KA) technique for TKA aims to reproduce the pre-arthritic knee anatomy, including both the femoro-tibial and femoro-patellar joints. An in silico study was conducted to compare 3 different femoral component sizing techniques to identify the anatomical landmark which allows closest restoration of the native trochlear anatomy. Our study's question was: what was the best method for sizing the femoral component when performing KA-TKA? It was hypothesized that sizing the femoral component by aiming to restore the groove height would be the best method to restore the native trochlear anatomy.

Methods

GMK sphere® (Medacta) femoral component 3D models were virtually kinematically aligned on 30 tri-dimensional (3D) bony osteoarthritis knee models. The femoral component was mediolaterally positioned to match distal native and prosthetic grooves. Three methods were used to size the femoral component: a conventional method with the anterior femoral cut flush to the femoral cortex (C-KATKA) and two alternative personalized methods aiming to recreate either the medial facet's height (ATM-KATKA) or the groove's height (ATG-KATKA). In-house analysis software was used to compare native and prosthetic trochlear articular surfaces and mediolateral implant overhangs.

Results

Compared with the C-KATKA, ATG-KATKA and ATM-KATKA techniques increased the component size by a mean of 0.90 (SD 0.31, min 0.5 to max 1.5) (p<0.001) and 1.02 (SD 0.31, min 0.5 to max 1.5) (p<0.001), respectively. C-KATKA technique substantially proximally understuffed the trochleae with maximum values of 7.11mm (SD 1.39, min 3.93mm to max 10.57mm) in the medial facet, 4.72mm (SD 1.27, min 1.46mm to max 6.86mm) in the lateral facet and 4.51mm (SD 1.40, min 1.92mm to max 7.30mm) in the groove, respectively. Alternative techniques understuffed medial facet with maximum values of 5.07mm (SD 1.29, min 2.83mm to max 8.34mm) and 4.70mm (SD 1.52, min 0.83mm to max 8.04mm) for ATG-KATKA and ATM-KATKA techniques, respectively. There was no significant understuffing of the groove or lateral facet for alternative techniques (ATM and ATG). The ATM-KATKA and ATG-KATKA techniques generated mediolateral implant overhang, mainly postero-lateral, with a rate of 90.0% and 86.7%, respectively. In this study, no mediolateral implant overhang was found for C-KATKA.

Discussion/conclusion

The C-KATKA technique substantially understuffs the native trochlear articular surfaces in medial, lateral and groove parts. Alternative techniques (ATM-KATKA and ATG-KATKA) for sizing the femoral component better restore the native trochlear anatomy but also generate a high rate of postero-lateral implant overhangs. Would this postero-lateral implant overhang be clinically deleterious remains unknown? The aspect ratio of contemporary femoral TKA implants can probably be optimized to allow a better anatomical restoration of the anterior femoral compartment.

Level of evidence

II, in silico study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total knee arthroplasty, Personalized, Anterior compartment, Trochlea offset, Biomechanics, Joint perception


Mappa


© 2023  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 110 - N° 2

Articolo 103769- aprile 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Total knee arthroplasty: Where are we after the “kinematic alignment” wave?
  • Matthew Arnold, Sébastien Lustig, Gilles Pasquier, J. Donald Hansom
| Articolo seguente Articolo seguente
  • Distal femoral torsion positioning in total knee arthroplasty shows equal reliability using a computer-assisted system or a robotic arm
  • Marie-Camille Sabaté Ferris, Baptiste Picart, Philippe Boisrenoult, Nicolas Pujol

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.