Modélisation informatique tridimensionnelle de la cavité orbitaire et des paupières - 13/02/25

Three-dimensional computer-assisted modeling of the orbital cavity and the eyelids

Doi : 10.1016/S0181-5512(06)77696-3 
F. Mann 1, , D. Gatinel 1, 2, S. Morax 1, T. Hoang-Xuan 1, 2
1 Services d’Ophtalmologie, Fondation ophtalmologique Adolphe de Rothschild, Paris 
2 Service d’Ophtalmologie, Hôpital Bichat-Claude Bernard, Paris 

Correspondance : F. Mann, Service d’Ophtalmologie, Fondation ophtalmologique Adolphe de Rothschild, 25, rue Manin, 75019 Paris.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Riassunto

Objectif

Ce travail a consisté à modéliser la cavité orbitaire et les principaux éléments constitutifs des paupières en utilisant les ressources de la conception tridimensionnelle assistée par ordinateur.

Méthode

Deux logiciels, Amapi Designer 7 et Carrara 3 Studio (Eovia, Mountain View, États-Unis), ont été utilisés pour obtenir les modèles. La synthèse des images a nécessité plusieurs étapes : la modélisation tridimensionnelle de la surface du crâne et la mise en place des principales structures palpébrales en utilisant des surfaces paramétriques ou polyédriques, la représentation de la vascularisation de l’orbite en nous aidant des repères osseux et musculaires intra-orbitaires, le plaquage d’une texture sur les différents éléments anatomiques (choix arbitraire d’une couleur), l’éclairage, le cadrage de la scène (choix de l’angle de prise de vue pour le rendu), le rendu (création d’un support numérique).

Résultats

Nous avons illustré trois techniques chirurgicales. Nous avons modélisé deux techniques classiquement décrites dans la chirurgie du ptôsis (réinsertion du muscle releveur de la paupière supérieure et résection conjonctivo-müllerienne) et avons détaillé la voie d’abord transconjonctivale inférieure (utilisée dans le traitement des lipoptoses palpébrales et dans l’abord du plancher orbitaire).

Conclusion

La modélisation 3D assistée par ordinateur permet d’obtenir des représentations graphiques réalistes et didactiques de structures anatomiques complexes comme l’orbite et son contenu. La qualité des images obtenues et la possibilité de représenter les étapes importantes d’une technique chirurgicale en font un outil pédagogique intéressant et prometteur.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Purpose

To develop a virtual model of the orbital cavity and the eyelids using a three-dimensional model.

Methods

Amapi Designer 7 and Carrara 3 Studio (Eovia, Mountain View, CA, USA) software were used to obtain 3D models of the orbital cavity and the eyelids. Three-dimensional creation is divided into two main processes. In the modeling process, a 3D model of the orbit, the arterial supply, and the eyelids are created using polygonal meshes and surgical tools with parametric surfaces. In the rendering process, colors are arbitrarily chosen to make elements in the model easier to read. A virtual camera is adjusted and light sources are created to produce virtual simulations of the orbit and the eyelids.

Results

Surgical techniques were illustrated with 3D models. Ptosis surgery (resection of the levator muscle and Müller’s muscle conjunctival resection) and the transconjunctival approach to lower eyelid blepharoplasty were described step by step.

Conclusion

Three-dimensional models have applications in many medical fields, providing representation of anatomical structures. They can be used to depict the anatomy of the orbital region in a realistic way. Three-dimensional computer-generated images are an aid in teaching residents in orbital anatomy and surgery.

Il testo completo di questo articolo è disponibile in PDF.

Mots-clés : Modélisation, orbite, paupières, ptôsis, enseignement

Key-words : Three-dimensional modeling, orbital cavity, eyelids, ptosis, education



© 2006  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 29 - N° 4

P. 381-390 - aprile 2006 Ritorno al numero
Articolo precedente Articolo precedente
  • Intérêt de l’auto-réfractomètre et de l’orbscan pour la mesure du diamètre pupillaire
  • C. Allouch, O. Touzeau, R. Kopito, V. Borderie, L. Laroche
| Articolo seguente Articolo seguente
  • Interféron et vasculites rétiniennes
  • C. Fardeau

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.