Abbonarsi

Incremental value of 2-dimensional speckle tracking strain imaging to wall motion analysis for detection of coronary artery disease in patients undergoing dobutamine stress echocardiography - 12/08/11

Doi : 10.1016/j.ahj.2009.09.010 
Arnold C.T. Ng, BSc(Med), MBBS a, b, Marta Sitges, MD, PhD c, Phuong N. Pham, B Med Sc (Hons) a, Da T. Tran, B Appl Sc (MRS) a, Victoria Delgado, MD b, Matteo Bertini, MD b, Gaetano Nucifora, MD b, Jane Vidaic, Grad Dip Hlth Sc a, Christine Allman, B Appl Sc (MRS) a, Eduard R. Holman, MD, PhD b, Jeroen J. Bax, MD, PhD b, , Dominic Y. Leung, MBBS, PhD a
a Department of Cardiology, Liverpool Hospital, University of New South Wales, Sydney, NSW, Australia 
b Department of Cardiology, Leiden University Medical Centre, Leiden, The Netherlands 
c Department of Cardiology, Thorax Institute, Hospital Clinic, IDIBAPS (Institut de Investigacions Biomediques August Pi i Sunyer), University of Barcelona, Barcelona, Spain 

Reprint requests: Jeroen J. Bax, MD, PhD, Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, 2333 ZA Leiden, The Netherlands.

Riassunto

Background

Interpretation of dobutamine stress echocardiogram (DSE) is often subjective and requires expert training. The purposes of this study was to determine optimal cutoff values for longitudinal, circumferential, and radial strains at peak DSE for detection of significant stenoses on coronary angiography and to investigate incremental value of combining strain measurements to wall motion analysis.

Methods

In this multicenter study, 102 patients underwent concomitant DSE and coronary angiography. Optimal cutoff values for mean global longitudinal (−20%), global circumferential (−26%), and mean radial (50%) strains at peak stress for detection of significant stenoses on coronary angiography were determined in a derivation group (n = 62) and tested in a prospectively recruited validation group (n = 40).

Results

Respective sensitivities for longitudinal, circumferential, radial strains, and expert wall motion score index (WMSI) were 84.2%, 73.9%, 78.3%, and 76%; respective specificities were 87.5%, 78.6%, 57.1%, and 92.9%; and respective accuracies were 85.2%, 75.7%, 70.3%, and 82.1%. Longitudinal strain analysis had comparable accuracy to WMSI (P = .70). However, combination longitudinal strain and WMSI had the highest sensitivity, specificity, and accuracy (100%, 87.5%, and 96.3% respectively), and its diagnostic accuracy was incremental to either longitudinal strain (P = .034) or WMSI alone (P = .008).

Conclusion

Longitudinal strain analysis had higher diagnostic accuracy than circumferential and radial strains and was comparable to WMSI for detection of significant coronary artery disease. However, combination longitudinal strain and WMSI resulted in significant incremental increase in diagnostic accuracy.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2009  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 158 - N° 5

P. 836-844 - novembre 2009 Ritorno al numero
Articolo precedente Articolo precedente
  • Achieving routine sub 30 minute door-to-balloon times in a high volume 24/7 primary angioplasty center with autonomous ambulance diagnosis and immediate catheter laboratory access
  • Miles Dalby, Rajesh Kharbanda, Gopal Ghimire, Jon Spiro, Phil Moore, Michael Roughton, Rebecca Lane, Mohammad Al-Obaidi, Molly Teoh, Elizabeth Hutchison, Mark Whitbread, David Fountain, Richard Grocott-Mason, Andrew Mitchell, Mark Mason, Charles Ilsley
| Articolo seguente Articolo seguente
  • Additional prognostic value of physical examination, exercise testing, and arterial ultrasonography for coronary risk assessment in primary prevention
  • Maxime Cournot, Dorota Taraszkiewicz, Jean-Pierre Cambou, Michel Galinier, Henri Boccalon, Hélène Hanaire-Broutin, Bernard Chamontin, Didier Carrié, Jean Ferrières

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.